Wear-Resistant Energy-Saving Centrifugal Blower Fan for Cement Plant Stoker System
Our stoker/feed blower fan is specially designed for cement plants, providing stable airflow with minimal energy consumption. The wear-resistant impeller and high-quality casing ensure long service life even in harsh industrial conditions.
Product Overview
Specifically engineered for cement plant applications, this centrifugal blower fan delivers reliable performance with optimized energy efficiency. The robust construction features wear-resistant components designed to withstand demanding industrial environments.
Key Features & Benefits
- Wear-resistant impeller for extended service life
- Energy-efficient operation reduces power consumption
- High-quality casing withstands harsh industrial conditions
- Stable airflow delivery for consistent performance
- Specifically designed for cement plant stoker systems
Technical Specifications
| Series |
Model |
Rotation Speed (r/min) |
Total Pressure (Pa) |
Air Capacity (m³/h) |
Power (kW) |
| 4-10 |
8D |
1450 |
2104~1400 |
16156~30993 |
18.55 |
| 4-10 |
9D |
960 ~ 1450 |
775 ~ 2668 |
15229 ~ 44128 |
11 ~ 37 |
| 10D |
730 ~ 1450 |
553 ~ 3301 |
15886 ~ 60533 |
7.5 ~ 55 |
| 11D |
730 ~ 1450 |
669 ~ 4003 |
21144 ~ 80570 |
11 ~ 90 |
| 12D |
730 ~ 1450 |
797 ~ 4777 |
25661 ~ 104600 |
15 ~ 132 |
| 14D |
730 ~ 1450 |
1086 ~ 6541 |
43591 ~166100 |
37 ~ 315 |
| 16D |
580 ~ 960 |
895 ~ 3709 |
51699 ~ 164150 |
45 ~ 185 |
| 18D |
580 ~ 960 |
1133 ~ 4710 |
73610 ~ 233730 |
75 ~ 280 |
| 20D |
580 ~ 960 |
1400 ~ 5837 |
100970 ~ 320610 |
110 ~ 520 |
| 4-10 |
22D |
480 ~ 960 |
1216 ~ 6865 |
116000 ~ 434000 |
140 ~ 850 |
| 25D |
480 ~ 730 |
1579 ~ 5138 |
171000 ~ 484000 |
165 ~ 700 |
| 28D |
375 ~ 730 |
1205 ~ 6400 |
187000 ~ 680000 |
320 ~ 1250 |
| 29.5D |
596 ~ 745 |
3236 ~ 7218 |
348000 ~ 810000 |
800 ~ 1600 |
If the parameters above do not meet your requirements, please contact us to inquire about custom specifications for your specific application needs.