Single-Channel β-Ray Dust and Noise Online Monitoring System
Overview
Based on the Beta Ray Attenuation Method, the system uses a C-14 source to measure particulate matter concentration by detecting beta radiation attenuation on the filter. It provides continuous online monitoring for construction sites, road works, factory boundaries, and other environmental applications.
Features
- Precise Particle Sizing: Mechanical particle sizing with intelligent dehumidification and PID flow control ensures accurate measurement and stable sampling.
- Flexible Calibration Adjustment: Automatic zero calibration and adjustable 3–60 min sampling intervals ensure reliable monitoring.
- Stable Constant Flow Sampling: Supports local data query and storage, with up to 35 days of data retention for efficient management.
- Intelligent Maintenance Management: Fog cannon linkage and remote management enable intelligent operation and maintenance.
Main Technical Parameters
| Parameter |
Specification |
| Range |
0-10000μg/m³ |
| Resolution |
0.1μg/m³ |
| Sampling Method |
Pump Suction Type |
| Power Supply |
AC 220V/50Hz |
| Working Environment |
-20~65℃/10%~95%RH |
| Consumption |
≤260W |
| Dimensions |
432mm × 346mm × 1400mm |
| Weight |
≤35kg |
| Data Transmission |
4G/RJ45 |
| Operation Method |
Touchscreen |