32 Series 300A (Overcurrent) Lithium Battery BMS Testing Machine With Computer And Cabinet CAN Communication
Key Functions
- Short circuit protection test (microsecond-level real short circuit protection testing)
- Drop test (detection of signal line disconnection or breakage)
- Self power consumption test (accurate measurement of individual section power consumption)
- Equalizing current and voltage (precise monitoring of balancing current and voltage)
These technologies represent years of engineering experience and research, providing stable performance without frequent upgrades.
Technical Parameters
- Input power: 180-240V, 50/60Hz, 1600W
- Operating voltage: 220V/50Hz AC (±10% fluctuation)
- Charging/discharging voltage: 5000mV - 90000mV
- Current accuracy: ±(0.1% FS + 0.1% RD)
- Voltage accuracy: ±(0.1% FS + 0.1% RD)
- Current resolution: 1mA
- Voltage resolution: 1mV
- Cycle capability: 1-9999 cycles
- Data logging with comprehensive test process tracking
- Data export to Excel and TXT formats
- RS232 interface for stable, real-time data acquisition
- Software calibration and external code scanning functionality
Testing Capabilities
- General performance testing
- Charge/discharge testing with voltage measurements
- ID resistance, NTC resistance, and on-resistance testing
- Single cell consumption current and equalization current testing
- Overcharge and over-discharge protection testing
- Charging and discharge over-current protection testing
- Simulated short circuit and over-temperature protection testing
- Precharge testing and MOSFET gate signal detection
Main Circuit Electrical Performance
| Parameter |
Specification |
| Voltage |
144000mV |
| Voltage Resolution |
1mV |
| Voltage Accuracy |
±0.1% |
| Charge/Discharge Current |
Overcurrent 300A (Max charging current 200A) |
| Current Resolution |
1mA |
| Current Accuracy |
±0.1% |
| Other Features |
Completely separated charging and discharging circuits |
Single String CELL Electrical Performance
| Parameter |
Specification |
| Voltage Output (each section) |
1000mV - 5000mV |
| Voltage Input (each section) |
1000mV - 5000mV |
| Voltage Resolution |
1mV |
| Voltage Accuracy |
±0.05% |
| Test Equalizing Current |
1000mA |
Power Box Electrical Performance (Overcurrent Test)
| Parameter |
Specification |
| Controllable Analog Current Range |
1A - 300A |
| Controllable Analog Current Accuracy |
±0.1% |
| Maximum Output Voltage |
5000mV |
Available Models
| Equipment Model |
Specifications |
| Protective Board Tester BP8858 |
1-24 series overcurrent 120A (max charging 50A) |
|
1-32 series overcurrent 120A (max charging 50A) |
|
1-24 series overcurrent 200A (max charging 100A) |
|
1-24 series overcurrent 200A (max charging 200A) |
|
1-32 series overcurrent 200A (max charging 100A) |
|
1-32 series overcurrent 200A (max charging 200A) |
|
1-32 series overcurrent 300A (max charging 200A) |