Specifications
Flow Rate Stability :
<0.1%
Eluent Concentration Range :
KOH、MSA-0.1~100.0mM
Flow Rate Setting Rate :
<0.1%
Pump Pressure :
0~42MPa
Column Capacity :
2pcs, 250mm And 150mm
Injection Volume :
10μL---4000μL
Quantitative Repeatability :
≤0.5%
Flow Rate Range :
0.001~12.000ml/min
Brand Name :
Wayeal
Model Number :
IC6600
Place of Origin :
Anhui, China
Certification :
CE
MOQ :
1 Unit
Price :
Negotiate
Packaging Details :
Wooden Case
Delivery Time :
35 days
Payment Terms :
T/T
Supply Ability :
30 Units/Month
Description

Introduction of IC6600 Ion Chromatography Instrument

The IC6600 multi-functional ion chromatograph features an innovative modular design, offering flexible configurations and powerful capabilities. Equipped with an all-PEEK pump head, it is resistant to acids, bases, and reversed-phase organic solvents, thereby preventing metal contamination. Additionally, the system can be flexibly configured with conductivity detectors, amperometric detectors, or UV detectors to meet a wide range of user detection needs.

Technical Parameters of IC6600 Ion Chromatography Instrument

Product Name Multifunctional Ion Chromatography
Model IC6600
Working power 220V, 50Hz
Ambient temperature 10-40°C
Relative humidity 20-85%
Qualitative repeatability ≤0.1%
Quantitative repeatability ≤0.5%
Pump flow rate range 0.001~12.000mL/min
Pressure resistance of pump head 0-40MPa
Flow setting error <0.1%
Flow stability <0.1%
Pressure display accuracy 0.001MPa
Pressure plusation <0.25%
Conductivity detector
Baseline noise ≤0.03%FS
Baseline drift ≤0.1%FS
Mini detectable concentration (Cl): ≤0.0001μg/mL
Mini detectable concentration (Li): ≤0.00005μg/mL
Mini detectable concentration (NO3): ≤0.001μg/mL
Mini detectable concentration (Na+): ≤0.001μg/mL
Mini detectable concentration (Ca2+): ≤0.005μg/mL
Conductivity cell volume ≤0.4μL
Conductivity detection range 0-45000μS/cm
Detector resolution 0.00238nS/cm
Conductivity cell temperature setting error ±0.01°C
Conductivity cell temperature display resolution 0.001°C
Conductivity cell temperature control range Detector temperature zone temperature +5°C-65°C
Conductivity cell temperature control stability 0.05°C
Conductivity cell temperature setting value error 0.1°C/h
Ampere detector
Type Thin-layer structure, automatic range
Driving voltage range -2.0V-2.0V
Drive voltage resolution 0.001V
Output signal range

Integral mode: 50pc-200uC

DC mode: 1pA-74μA

Noise

Integration mode<30pC

DC mode<5pA, DC mode static noise<1pA

Cell material Titanium
Pool volume <0.2μL
Maximum pool pressure 0.7MPa
Minimum detectable concerntration I-0.001μg/mL
Minimum detectable concerntration fructose 0.01μg/mL
UV Detector
Wavelength indication error 0.1nm
Wavelength repeatability 0.1nm
Mini detectable concentration BrO3-0.0005μg/mL
Mini detectable concentration CrO42-0.001μg/mL
Qualitative repeatability ≤0.05%
Quantitative repeatability ≤0.3%
Suppressor
Dead volume 50μL
Inhibition capacity 170ueq/min
Pressure resistance 3MPa
Column oven
Temperature range Room temperature +5°C~70°C
Temperature control stability 0.1°C/h
Error of temperature setting value 0.05°C
Autosampler
Number of samples ≥120 (1.5ml sample bottle)
Temperature 4~30°C
Linear >0.999
Cross-contamination <0.01%

Send your message to this supplier
Send Now

IC6600 Ion Chromatography Instrument With Reagent-free Eluent Generator

Ask Latest Price
Flow Rate Stability :
<0.1%
Eluent Concentration Range :
KOH、MSA-0.1~100.0mM
Flow Rate Setting Rate :
<0.1%
Pump Pressure :
0~42MPa
Column Capacity :
2pcs, 250mm And 150mm
Injection Volume :
10μL---4000μL
Contact Supplier
IC6600 Ion Chromatography Instrument With Reagent-free Eluent Generator

Anhui Wanyi Science and Technology Co., Ltd.

Verified Supplier
5 Years
anhui, hefei
Since 2003
Business Type :
Manufacturer
Total Annual :
120000000-130000000
Employee Number :
1000~1300
Certification Level :
Verified Supplier
Contact Supplier