Wayeal IC6200 Ion Exchange Chromatography System for Cations and Anions Analysis
Introduction of Ion Exchange Chromatography Instrument
Ion chromatography is used for water chemistry analysis. Ion chromatographs are able to measure concentrations of major anions, such as fluoride, chloride, nitrate, nitrite, and sulfate, as well as major cations such as lithium, sodium, ammonium, potassium, calcium, and magnesium in the parts-per-billion (ppb) range. Concentrations of organic acids can also be measured through ion chromatography.
Features of Ion Exchange Chromatography Instrument
1. Intergrated apperance design, high brightness LCD full touch GUI controller
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.
5. One-button operation, the system can realize automatic cleaning after the analysis is completed to ensure the cleaning effect
Technical Data of Ion Chromatography Instrument
|
System Parameter
|
|
|
Qualititative Repeatability
|
≤0.05%
|
|
Quantitative Repeatability
|
≤0.2%
|
|
Pump System
|
|
|
Flow Rate (Full PEEK Pump)
|
(0.001–12.000) mL/min
|
|
Pump Head Pressure Resistance
|
(0–42) MPa
|
|
Flow Rate Set Error
|
≤ ±0.1%
|
|
Flow Rate Stability
|
≤ ±0.1%
|
|
Pressure Display Resolution
|
0.01 MPa
|
|
Suppressor
|
|
|
Suppressor Type
|
Electrolytic self-regenerating membrane suppressor
|
|
Constant Current Range
|
0–500 mA, adjustable in increments of 1 mA
|
|
Column Oven
|
|
|
Temperature Range
|
Ambient +5°C to 85°C
|
|
Temperature Stability
|
±0.01°C
|
|
Compatibility
|
Compatible with 250 mm and 150 mm length columns
|
|
AS2800 Series Autosampler
|
|
|
Quantitative Repeatability
|
< 0.5% RSD (full-loop injection)
|
|
Sample Positions
|
48 positions / 11 positions
|
|
Wash Ports
|
2 ports (fine wash and coarse wash)
|
|
Operating Temperature
|
10–40°C
|
|
Vial Types
|
5mL/ 100mL
|
|
Injection Volume
|
10 µL – 4000 µL (depending on sample loop size)
|
|
Single Injection Cycle Time
|
Approx. 20s (depending on wash time and injection volume)
|
|
Injection Mode
|
Full-loop injection
|
|
AS3110 Series Autosampler
|
|
|
Sample Capacity
|
64/120 positions
|
|
Cooling Temperature Range
|
4–30°C
|
|
Repeatability
|
< 0.3% RSD (full-loop injection, injection volume > 5 µL)
|
|
Syringe Specifications
|
Standard: 500 µL; Optional: 250 µL, 1000 µL, 2500 µL
|
|
Sample Loop Specifications
|
Standard: 100 µL; Optional: 25 µL, 50 µL, 200 µL
|
|
Carryover (Cross Contamination)
|
< 0.01%
|
Industry Application
Some typical applications of ion chromatography include:
- Drinking water analysis for pollution and other constituents
- Determination of water chemistries in aquatic ecosystems
- Determination of sugar and salt content in foods
- Isolation of select proteins