IEC 60335-1 UVC Aging Test Chamber Tower Type UVC 254 Light Source 5W/㎡~10W/㎡
Product information:
Using low-pressure mercury lamp UV-C (254nm) as the radiation source, by changing and controlling the light irradiance, blackboard temperature, condensation, rain, etc., the comprehensive conditions of outdoor ultraviolet light, humid heat condensation and rainfall are simulated, and the aging test is performed on the samples. The equipment mainly emits ultraviolet light at 254nm and is mainly used for the aging assessment of internal materials of household appliance disinfection equipment and the aging assessment of aerospace materials outside the atmosphere. At present, the main applicable standards for UV-C are GB4706.1 GB/T 17554.1 IEC 60335-1.
◆Adopt ultraviolet lamp UV-C 254
◆ UV-C ultraviolet light: wavelength 200 ~ 275nm, also known as short-wave sterilizing ultraviolet light. The peak irradiance is 253.7nm. It mainly emits UVC short-wave ultraviolet light.
Main technical parameters:
●Light source: UVC 254
●Service life: 2000 hours
●Irradiance range: UVC254nm: 5W/㎡~10W/㎡
●Blackboard temperature range: 40℃~80℃
●Condensation:√
● Rain:√
●Sample racks: 24 (300mm*75mm) can hold 48 standard samples.
● Sample rain: √
● Total exposure area: 5175c㎡
● Dimensions: Width: 147cm
Depth: 56cm
Height: 135cm
● Weight: 170KG
● Power supply: AC220V, 10A, well grounded
● Water source: National laboratory level 3 water, water pressure: 0.15Mpa~0.3Mpa
● Configuration: 1 UV aging test chamber, 8 UVC lamps (Not equipped with: pure water machine)
Features:
1. Use mercury lamp as light source, and simulate outdoor UV, humid heat condensation or rainfall and other comprehensive conditions by changing and controlling light irradiance, blackboard temperature, condensation or rain, and conduct aging test on samples.
2. 6 editable test methods, users can set various test parameters and processes according to the required test standards and needs.
3. The test chamber automatically cycles according to the test parameters, and automatically stops when the test ends.
Complies with the ultraviolet test requirements in standard ETAG 002.
Test cycle process time adjustable range: 0~9999 hours
4. Use UVC254nm ultraviolet light tube, the light radiance control range is:
5. Condensation or exposure to rain:
Blackboard temperature is automatically controlled.
Safety protection of water level and water temperature.
6. 24 sets of sample racks, 75*300mm, that is, two 75*150mm sample racks.
7. Protection:
Automatic shutdown and alarm when the box is over-temperature.
Automatic shutdown and alarm when the water level in the tank is low.
Overcurrent protection.