Product Overview
The CSHV Series are open-loop Hall-effect current sensors utilizing patented Honeywell technology for superior performance and reliability in current sensing applications. These non-intrusive, electrically isolated sensors offer a simple sensing method with primary current measurement ranges from 100 A to 1500 A dc. AEC-Q100 qualified, they are ideal for motor control, battery management, and fault detection in electrified vehicles and industrial equipment. Customizable solutions and global technical support are available.
Product Attributes
- Brand: Honeywell
- Certifications: CE, UKCA, REACH, RoHS compliant, AEC-Q100 qualified
- Housing material: PBT + GF30 %
- Mounting screw: M4, 2,5 N m torque max.
- Mating electrical connector: TE MPN 1473672-1
- Weight: 58 g
Technical Specifications
| Catalog Listing | Measure Range (A) | Sensitivity (mV/A at VS = 5 V) | Offset (mV at VS = 5 V) | Accuracy (% at VS = 5 V) 25C | Accuracy (% at VS = 5 V) -40C to 85C | Accuracy (% at VS = 5 V) -40C to 125C | Offset (mV) -40C to 85C | Offset (mV) -40C to 125C |
| CSHV100A-001 | 100 | 20 | 7 mV | 1 % | 2 % | | 25 mV | |
| CSHV200A-001 | 200 | 10 | 7 mV | 1 % | 2 % | | 15 mV | |
| CSHV300A-001 | 300 | 6.667 | 7 mV | 1 % | 2 % | | 18 mV | |
| CSHV400A-001 | 400 | 5 | 7 mV | 1 % | 2 % | | 13 mV | |
| CSHV500A-001 | 500 | 4 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV600A-001 | 600 | 3.333 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV700A-001 | 700 | 2.857 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV800A-001 | 800 | 2.5 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV900A-001 | 900 | 2.222 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV1000A-001 | 1000 | 2 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV1100A-001 | 1100 | 1.818 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV1200A-001 | 1200 | 1.667 | 7 mV | 1 % | 2 % | | 10 mV | |
| CSHV1500A-001 | 1500 | 1.333 | 7 mV | 2 % | 3 % | 2 % | 10 mV | 10 mV |
| Characteristic | Symbol | Unit | Parameter | Condition | Min. | Typ. | Max. |
| Supply voltage max. | VS max. | V | | | | | 10 |
| Reverse supply voltage max. | VR max. | V | | | -0.3 | | |
| Output voltage max. | VOUT max. | V | | | -0.3 | | 10 |
| Output reverse/forward voltage | | V | | | | | |
| Output current max. | IOUT max. | mA | | | -10 | | 10 |
| Ambient storage temperature | | C | | | -40 | | 125 |
| Electrostatic discharge voltage | VESD | kV | | | | | 8 |
| RMS voltage for AC isolation test | VDWV | kV | | 50 Hz, 1 min | | 2.5 | |
| Creepage distance | dCp | mm | | | 4.9 | | |
| Clearance | dCl | mm | | | 4.9 | | |
| Comparative tracking index | CTI | | PLC3 | | | | |
| Primary current, nominal DC | IPN | A | | | -IPN | | IPN |
| Supply voltage | VS | V | | | 4.5 | 5 | 5.5 |
| Output voltage (at IP = 0) | VOS | V | | | | 2.500 | |
| Electrical offset voltage | VOS, ELECT | mV | | TA = 25C, VS = 5 V | | 3 | |
| Magnetic offset voltage | VOS, MAG | mV | | TA = 25C, VS = 5 V | | 2 | |
| Current consumption | ISUPPLY | mA | | TA = 25C, VS = 5 V | | | 13 |
| Load resistance | RL | Ohm | | | 10k | | |
| Output impedance | Rout | Ohm | | | | 1 | |
| Ratiometric error | r | % | | TA = 25C | | 0.5 | |
| Sensitivity | G | mV/A | | TA = 25C | | 2000/IPN | |
| Sensitivity error: 100 A to 1200 A | g | % | | TA = 25C, VS = 5 V | | | 0.6 |
| Sensitivity error: 1500 A | g | % | | TA = 25C, VS = 5 V | | | 0.8 |
| Linearity error | L | % | of full scale output | | -1 | | 1 |
| Ambient operating temperature | | C | | | -40 | | 125 |
| Average temperature coefficient VOS, ELECT | | mV/C | | | | 0.04 | |
| Average temperature coefficient of G | | %/C | | | | 0.02 | |
| Step response time (10 % to 90 %) | tr | s | | | | 2 | 6 |
| Frequency bandwidth | BW | kHz | | -3 dB | 45 | | |
| Output RMS noise (RMS) | | mV | | | | | 2 |