Used for testing fabric recoverability after being creased. Features intelligent measurement with CCD imaging and computer-controlled processing.
GB/T3819, ISO2313, AATCC66, M&S, and other relevant standards.
National Patent: 200820121051.X
| Parameter | Specification |
|---|---|
| Working Pattern | Computer controlled, Rotary-position, CCD imaging, automatic computer processing of images and data |
| Imaging Sensor | CCD |
| Measuring Method | Fast elastic: 15±1s, Slow elastic: 5min±5s |
| Pressure Load | 10±0.05N |
| Pressured Time | 5min±5s |
| Pressured Area | 18×15mm |
| Angle Measuring Accuracy | 0~180±0.1° |
| Work Position | 10 digits |
| Power Source | AC220V 50Hz 120W |
| External Dimension | 600×550×680mm |
| Weight | 65 kg |