features:
Product Description
| FPC | Cut | LED | CCT(K) | CRI | SDCM | Beam angle | LEDs/m | Lumens | Voltage | Current | Cut | Max Run |
| Width | Length | (lm/m) | (mA/m) | Length | ||||||||
| 10mm | 50mm | 5050RGBW | R:620-630nm | 80/90 | / | 120° | 70 | R:9lm/W | 24V | 600mA | 50mm | 5m |
| G:520-530nm | G:20lm/W | |||||||||||
| B:465-475nm | B:5lm/W | |||||||||||
| W:2700-6500K | W:50m/W |

Other Specifications
| Protection grade | IP67 |
| Working temperature(°C) | -25~+60 |
| Storage environment temperature (°C) | -25~+70 |
| Standard length | 5 |
| Maximum cascade length(m) | 5 |
| weight | / |
Remark
The test environment temperature is 25±2°C;
The above data are typical values, the actual parameters of the product may be different from the typical data; the data is subject to change without notice;
The above "/" means that this parameter is not required for the time being.




Common product faults and their troubleshooting methods
| Fault Phenomena | Possible Causes | Troubleshooting Methods |
| All lights off | 1.Mains power failure | Power on |
| 2.0pen circuit or short circuit at switching power supplyoutput triggering auto-protection | Troubleshoot and restore power | |
| 3.Reverse polarity at LED strip power input | Check wire connection status to ensure correct polarity | |
| Partial lights off | 1.Partial switching power supply failure | Inspect power supply system and resolve faults |
| 2.Wiring error in partial LED strip circuits | ||
| 3.Reverse polarity in partial LED strips | Correct wiring | |
| LED uneven brightnessor insufficient brightness | 1.Power supply overload | Replace with higher-power supply according to load |
| 2.Excessive line loss in switching power circuits orsignificant line loss discrepancies | Maintain LED strip operating voltage within +5% of rated voltage 1. Shorten power cable length between power supply and LEDstrip or use larger gauge wires; 2. Ensure number of LED strips per circuit ≤ max allowed cascadingquantity and keep cascading quantities similar per circuit). | |
| 3.Excessive serial connection of LED strips | Adjust LED strip quantity per power branch to meet maxallowed cascading requirements per circuit | |
| LED flickering | 1.Poor contact at connection points | Identify and resolve poor contact points |
| 2.Switching power supply malfunction | Replace switching power supply |

- If the external flexible cable of this product is damaged, the cable must be replaced by the manufacturer or similarly qualified personnel to prevent hazards.
- For specific installation arrangements and precautions, refer to the product user manual.
- Data in this specification is based on standard products, Actual delivered products may vary, subject to physical measurements.
- All product diagrams in this specifcation are schematic diagrams, Actual delivered products may differ, subject to physical obiects
- Technical modifications may be implemented without prior notice.
- Shenzhen Meishang Lighting Co., Ltd. reserves the final interpretation rights of this manual.