BTS-5V6A Battery Testing Equipment (Double Range)
Equipment Model : 5V6A Battery Testing System Equipment Item Code:CT-4008-5V6A-S1
| 
			 Project index  | 
			
			 Parameter index  | 
		|
|---|---|---|
| Input Power | AC 220V ±10% / 50Hz | |
| resolution | AD:16bit;DA:16bit | |
| Input Resistance | ≥1MΩ | |
| Input Power | 426W | |
| Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
| Channel Control Mode | Independent Control | |
| Voltage | Per Channel Voltage Range | Charge:25mV~5V; Discharge:1V-5V | 
| Discharge Min Voltage | 10mV | |
| Accuracy | ± 0.05% of FS | |
| Stability | ± 0.05% of FS | |
| Current | Per Channel Current Range | Range 1: 0.0005A-0.1A Range 2: 0.1A~6A | 
| Accuracy | ± 0.05% of FS | |
| Stability | ± 0.05% of FS | |
| Power | Per Channel Output Power | 30W | 
| Stop current | Range 1: 0.2mA Range 2: 12mA | |
| Stability | ± 0.1% of FS | |
| Time | Current Response Time | 1ms (0-Full Range) | 
| Step Time Range | 
			 ≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms)  | 
		|
| Data Recording | Record Condition | Min Time:100mS | 
| Min Voltage:10mV | ||
| Min Current:Range 1: 0.2mA Range 2: 12mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | 
			 Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,Constant Power Charge  | 
		
| End Conditon | Voltage,Current,Relative Time,Capacity,-△V | |
| Discharge | Discharge Mode | CCD,CPD,CRD | 
| End Condition | Voltage,Current,Relative Time,Capacity,-△V | |
| Pulse | charge | CCC,CPC | 
| Discharge | CCD,CPD | |
| Min Pulse Width | 500ms | |
| Automated Switch | Automated swith from charge to discharge for each pulse | |
| End Condition | Voltage, Test Time | |
| Cycle | Loop Measure Range | 1~65535 times | 
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested loop Function,Max Support 3 Layers | |
| Protection | Software Protection | 
			
  | 
		
			
  | 
		||
			
  | 
		||
| Hardware Protection | Additional Anti-reverse Protection Model | |
| Voltage and Current Test Sampling | 4-wire connecting | |
| Noise | <85dB | |
| Database | MySQL Database | |
| A Means of Communication of Upper Machine | TCP/IP Protocol | |
| Data Output | EXCEL,TXT,Graph | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 8 | |
| Dimensions | 3U,480*330*130(mm) | |
Equipment Working Environment
| Working Temperature Range | 0℃~40℃ | 
| Storage Temperature Range | -10℃~50℃ | 
| Working Environment Relative Humidity Range | ≤70% RH | 
| Storage Environment Relative Humidity Range | ≤80% RH |