Due to its many measurement functions and ranges, DMM is described as a representative value for basic accuracy.
For accuracy of each range, please refer to the sample PDF
| DC voltage | 419.9mV~600V, 5 ranges, basic accuracy: ±1.3% rdg. ±4dgt. |
|---|---|
| AC voltage / 50~500Hz | 4. 199V~600V, 4 ranges, basic accuracy: ±2.3% RDG. ±8dgt. (average) |
| Resistance | 419.9 Ω~41.99 MΩ, 6 ranges, basic accuracy: ± 2.0% rdg. ±4 dgt. |
| Continuity check | Threshold: 50Ω ± 40Ω |
| Diode inspection | Judge only clockwise: open port voltage: below 3.4V, test current: below 800μA |
| Automatic power-saving function | Yes (can be canceled) |
| Display | Digital/LCD, up to 4199 dgt. |
| Sampling rate | 2.5 times/s |
| Power supply | Button Battery CR2032*1, continuous usage time: 150h (when measuring DC voltage), 30h (pen light on for 10 seconds / off for 20 seconds, when measuring DC voltage) |
| Volume and weight | 30W*182H*26.5Dmm,80g |
| Attachment | User Manual* 1, button lithium battery (CR2032) *1 (built-in main unit), protective case (red/black, 1 each) |