Specifications
Brand Name :
FLUKE
Model Number :
Fluke 283 FC/PV
Place of Origin :
usa
MOQ :
1
Price :
250$-500$
Payment Terms :
T/T
Delivery Time :
1week
Recording Capability :
Min/Max/Average with elapsed time
Limit Gauge :
User-defined
Function :
FieldSense validation
Responsetime :
Less than 1 second
Environmental Protection :
Waterproof & dustproof
Input Impedance :
10 meg ohm
Socket Type :
Standard and GFCI
Memory Capacity :
15,000 recorded events
Description
Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp

Model#: FLUKE-283FC/PVPart#: 6019841

Key features
  • CAT III 1500 V/CAT IV 1000 V safety rated multimeter, wireless current clamp and test leads
  • Includes CAT III 1500 V rated Staubli MC4 MC4 test leads
  • User-defined limit gauge for quick go/no-go decisions
  • Unique multimeter readiness self-check
  • Visual and audio polarity indicators with on/off function wiring issues
Specifications: Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp
283 FC Digital Multimeter
Function Range Resolution Accuracy
AC volts[1] 6.000 V 0.001 V 1.0 % + 3
(45 Hz to 500 Hz)
60.00 V 0.01 V
600.0 V 0.1 V 2.0 % + 3
(500 Hz to 1 kHz)
1000 V 1 V
DC volts 6.000 V 0.001 V 0.09 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1500 V 1 V 0.15 % + 2
AC mV[1] 600.0 mV 0.1 mV 1.0% + 3 (45 Hz ~ 500 Hz)
2.0% + 3 (500 Hz ~ 1000 Hz)
DC mV 600.0 mV 0.1 mV 0.09 % + 2
Continuity 600 Ω 1 Ω
Resistance 600.0 Ω 0.1 Ω 0.5 % + 4
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 4
Capacitance 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF 1 μF 10 % typical
Frequency 99.99 Hz 0.01 Hz 0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
AC VA (45~500Hz)[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
60.00 kVA 0.01 kVA 2 % + 0.15 kVA
DC VA[1] 360.0 VA 0.1 VA 2 % + 1.0 VA
3.600 kVA 0.001 kVA 2 % + 0.01 kVA
36.00 kVA 0.01 kVA 2 % + 0.1 kVA
90.00 kVA 0.01 kVA 2 % + 0.25 kVA
Min-max avg For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.
For AC functions, accuracy is the specified accuracy of the measurement function ± 40 counts for changes longer than 900 ms in duration.
Send your message to this supplier
Send Now

Fluke 283 FC/PV Solar Digital Multimeter And Wireless Current Clamp

Ask Latest Price
Brand Name :
FLUKE
Model Number :
Fluke 283 FC/PV
Place of Origin :
usa
MOQ :
1
Price :
250$-500$
Payment Terms :
T/T
Contact Supplier
Fluke 283 FC/PV Solar Digital Multimeter And Wireless Current Clamp

Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.

Verified Supplier
1 Years
Shaanxi, xianyang
Since 2018
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Exporter, Trading Company, Seller
Total Annual :
5000000-10000000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier