Specifications
Payment Terms :
T/T
Secondary Side Supply Water :
40
Filtration Accuracy :
50 / 25
Brand Name :
Hailos
Power Supply :
AC 3/N/PE 380~480V 50/60Hz DC 800V
Model Number :
DWW2400-125A
Primary Side Supply Water :
36
MOQ :
1
Delivery Time :
5-8 weeks
Dimensions :
900*1200*2200
Packaging Details :
Cartons
Secondary Side Connection :
DN100
Place of Origin :
China
Price :
$10000~$50000
Secondary Side Flow Rate :
90
Supply Ability :
500sets /month
Cooling capacity :
1200kW
Certification :
ISO、CE
Description

Product Introduction

Dual-pump redundancy design enables automatic switchover to the standby pump in the event of a single-pump failure.
High-efficiency stainless steel plate heat exchanger featuring a compact structure and superior corrosion resistance.
All internal piping is made of stainless steel, ensuring a clean, contamination-free system.
Equipped with a PLC controller from a renowned international brand for guaranteed safety.
Intelligent PLC control program monitors and regulates the unit to ensure safe and stable operation.
Expert-level fault diagnosis simplifies operation and maintenance.
Supports Modbus RTU; TCP/IP connectivity is available as an option.
User-friendly color HMI allows management personnel to monitor the unit's operating status in real time.
Touchscreen supports multi-level password protection to safeguard information security.

Technical Parameters

Parameter Unit DWW300-65A DWW600-80AW DWW600-80AN DWW1200-100A DWW2400-125A
Cooling Capacity kW 300 600 600 1,200 2,400
Secondary Side Supply Water ℃ 40
Secondary Side Flow Rate m³/h 26 52 52 90 180
Secondary Side Connection DN DN65 DN80 DN80 DN100 DN125
ATD ℃ 5 5 4 4 4
Filtration Accuracy μm 50 50 50 / 25 50 / 25 50 / 25
Secondary Side External Output Pressure Difference kPa ≥120 ≥120 ≥120 ≥120 ≥120
Number of Pumps N/A 1+1 redundancy 1+1 redundancy 1+1 redundancy 1+1 redundancy 2+1 redundancy
Primary Side Supply Water ℃ 35 35 36 36 36
Primary Side Flow Rate m³/h 26 52 52 90 180
Primary Side Connection DN DN50 DN80 DN80 DN100 DN125
Rated Power kW 4.5 8 10.5 22.5 44.5
Primary Side Pressure Drop kPa ≤100 ≤100 ≤120 ≤150 ≤150
Power Supply / AC 3/N/PE 380~480V 50/60HZ
DC 800V
Unit Dimensions - Width mm 600 900 600 600 900
Unit Dimensions - Depth mm 1200
Unit Dimensions - Height mm 2,000 2,000 2,000 2,200 2,200

Product Photo

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

Certificate ( CE /ISO )

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster


Packing

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster


Project Case

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

FAQ

Q1: Who is Zhengzhou Hailos Refrigeration Equipment Co.,ltd?

A1: We are a professional factory specializing in R&D, production and export of precision air conditioners and industrial chillers, located in Zhengzhou, China. We focus on high-precision cooling equipment for data centers, laboratories, laser processing, electroplating, battery factories, medical rooms and industrial production lines. All units are strictly tested before delivery, with complete international certifications for global market sales.

Q2: What is your MOQ (Minimum Order Quantity)?

A2: 1 unit for standard models is acceptable; for customized non-standard machines, MOQ depends on configuration. Distributors with bulk orders get extra factory discount.

Q3: Do you accept factory inspection?

A3: Yes, warm welcome customers to visit our workshop and test equipment on site. We support live video factory tour if you cannot come to China temporarily.


Q4: Where are Hailos precision air conditioners widely used?

A4: Server data room, communication base station, medical lab, testing laboratory, battery workshop, optical equipment room, clean room, electronic manufacturing workshop, industrial control cabinet cooling.

Q5: Can precision air conditioner work all year round without shutdown?

A5: Yes. Our precision cooling units adopt heavy-duty scroll compressor, EC energy-saving fan and independent control system, designed for 24-hour non-stop operation all year long, low failure rate.

Q6: Can I adjust temperature and humidity remotely?

A6: Standard models support Modbus communication to connect with monitoring system; optional WiFi remote control module for mobile phone real-time parameter checking, alarm reminder and parameter modification.

Q7: What refrigerants do you use for precision AC?

A7: Mainly eco-friendly R410A, R134a; we can replace with R32, R290 low-GWP refrigerants to meet local environmental regulations in your country.

Q8: Do you support OEM / ODM customized service?

A8: Yes, full OEM & ODM service available: custom unit size, voltage (380V/220V/415V 50/60Hz), brand logo, control panel language (English, Spanish, Russian, Vietnamese), special refrigerant, remote monitoring system, cabinet color. We can design new model drawing based on your working conditions.

Q9: Do you provide technical drawing and parameter sheet?

A9: Yes. After confirming the model, we supply dimension drawing, technical datasheet, wiring diagram, installation manual in English PDF files for your project design.

Q10: Can you supply spare parts separately?

A10: Yes, we offer all replacement spare parts: compressor, fan motor, controller, filter, expansion valve, sensor.
Send your message to this supplier
Send Now

1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

Ask Latest Price
Payment Terms :
T/T
Secondary Side Supply Water :
40
Filtration Accuracy :
50 / 25
Brand Name :
Hailos
Power Supply :
AC 3/N/PE 380~480V 50/60Hz DC 800V
Model Number :
DWW2400-125A
Contact Supplier
1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster
1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster
1200kW Cabinet Type CDU Coolant Distribution Unit, Liquid to Liquid Cooling for AI Data Center HPC Cluster

Zhengzhou Hailos Refrigeration Equipment Co.,ltd

Verified Supplier
1 Years
henan, zhengzhou
Since 2016
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter
Total Annual :
4.4 millions-USD 4.6 millions
Employee Number :
>56
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement