Specifications
Secondary connection :
DN125
Certification :
ISO、CE
Secondary flow rate :
105 m³/h
Model Number :
L35
Power supply :
460-480V 3Ph 60Hz
MOQ :
1
Delivery Time :
5-8 weeks
Payment Terms :
T/T
Dimensions :
1200W x 1400D x 2200H mm
Price :
$3000~$8000
Supply Ability :
500sets /month
Cooling capacity :
1200kW
Brand Name :
Hailos
Packaging Details :
Cartons
Rated power :
16.5kW
Place of Origin :
China
Description

Product Introduction

Engineered for extreme AI server racks (100kW+ per cabinet), the DWW1200-125A manages massive heat loads with 1200kW capacity and 105 m³/h secondary flow. Its 1+1 redundant pumps and stainless steel heat exchanger isolate facility water from dielectric coolant, protecting GPUs. Seamlessly integrates into air-liquid hybrid micro-modules via PLC Modbus TCP/IP.


Key Parameters:

  • Model: DWW1200-125A (1200kW), DWW500-80A (500kW), DWW200-50A (200kW)
  • Secondary Interface: DN125 (1200kW), DN80 (500kW), DN50 (200kW)
  • Temp Control: 40/50°C secondary, 35/45°C primary
  • Footprint: 1200W x 1400D x 2200H mm (1200kW model)
  • Electrical: 16.5kW rated power, 460-480V 3Ph 60Hz ready.
    Applications:​ GB200/H100 GPU clusters, AI training centers, high-performance computing (HPC), and large-scale AIDC facilities.

Technical Parameters

Parameter Unit DWW200-50A DWW500-80A DWW1200-125A
Cooling Capacity kW 200 500 1200
Secondary Side Supply/Return Water Temp. °C 40/50 40/50 40/50
Secondary Side Flow Rate m³/h 18 45 105
Secondary Side Connection DN DN50 DN80 DN125
Primary Side Supply/Return Water Temp. °C 35/45 35/45 35/45
Primary Side Connection DN DN50 DN80 DN125
Rated Power kW 4.5 9 16.5
Primary Side Pressure Drop kPa ≤100 ≤100 ≤100
Power Supply 380V415V, 3Ph, 50/60Hz; 460V480V, 3Ph, 60Hz (common to all models)

Product Photo

1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger


Certificate ( CE /ISO )

1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger


Packing

1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger


Project Case

1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger

FAQ

Q1: Who is Zhengzhou Hailos Refrigeration Equipment Co.,ltd?

A1: We are a professional factory specializing in R&D, production and export of precision air conditioners and industrial chillers, located in Zhengzhou, China. We focus on high-precision cooling equipment for data centers, laboratories, laser processing, electroplating, battery factories, medical rooms and industrial production lines. All units are strictly tested before delivery, with complete international certifications for global market sales.

Q2: What is your MOQ (Minimum Order Quantity)?

A2: 1 unit for standard models is acceptable; for customized non-standard machines, MOQ depends on configuration. Distributors with bulk orders get extra factory discount.

Q3: Do you accept factory inspection?

A3: Yes, warm welcome customers to visit our workshop and test equipment on site. We support live video factory tour if you cannot come to China temporarily.


Q4: Where are Hailos precision air conditioners widely used?

A4: Server data room, communication base station, medical lab, testing laboratory, battery workshop, optical equipment room, clean room, electronic manufacturing workshop, industrial control cabinet cooling.

Q5: Can precision air conditioner work all year round without shutdown?

A5: Yes. Our precision cooling units adopt heavy-duty scroll compressor, EC energy-saving fan and independent control system, designed for 24-hour non-stop operation all year long, low failure rate.

Q6: Can I adjust temperature and humidity remotely?

A6: Standard models support Modbus communication to connect with monitoring system; optional WiFi remote control module for mobile phone real-time parameter checking, alarm reminder and parameter modification.

Q7: What refrigerants do you use for precision AC?

A7: Mainly eco-friendly R410A, R134a; we can replace with R32, R290 low-GWP refrigerants to meet local environmental regulations in your country.

Q8: Do you support OEM / ODM customized service?

A8: Yes, full OEM & ODM service available: custom unit size, voltage (380V/220V/415V 50/60Hz), brand logo, control panel language (English, Spanish, Russian, Vietnamese), special refrigerant, remote monitoring system, cabinet color. We can design new model drawing based on your working conditions.

Q9: Do you provide technical drawing and parameter sheet?

A9: Yes. After confirming the model, we supply dimension drawing, technical datasheet, wiring diagram, installation manual in English PDF files for your project design.

Q10: Can you supply spare parts separately?

A10: Yes, we offer all replacement spare parts: compressor, fan motor, controller, filter, expansion valve, sensor.
Send your message to this supplier
Send Now

1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger

Ask Latest Price
Secondary connection :
DN125
Certification :
ISO、CE
Secondary flow rate :
105 m³/h
Model Number :
L35
Power supply :
460-480V 3Ph 60Hz
MOQ :
1
Contact Supplier
1200kW Liquid Cooling CDU for AI Data Centers with 1+1 Redundant Pumps and Stainless Steel Heat Exchanger

Zhengzhou Hailos Refrigeration Equipment Co.,ltd

Verified Supplier
1 Years
henan, zhengzhou
Since 2016
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter
Total Annual :
4.4 millions-USD 4.6 millions
Employee Number :
>56
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement