| Quantity | 1 |
| Continuous current | 3.6 Aeff |
| Reduction of continuous current depending on ambient temperature | |
| Mains input voltage: 110 VAC | |
| Switching frequency 5 kHz | No reduction |
| Switching frequency 10 kHz | No reduction |
| Switching frequency 20 kHz | No reduction |
| Mains input voltage: 230 VAC | |
| Switching frequency 5 kHz | No reduction |
| Switching frequency 10 kHz | No reduction |
| Switching frequency 20 kHz | No reduction |
| Reduction of continuous current depending on installation elevation | |
| Starting at 500 m above sea level | 0.36 Aeff per 1000 m |
| Peak current | 12 Aeff |
| Nominal switching frequency | 10 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. motor line length | 15 m |
| Protective measures | |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| Terminal connection cross section | |
| Flexible and fine-stranded wires | |
| With wire end sleeves | 0.25 to 4 mm² |
| Approbation data | |
| UL/C-UL-US | 30 to 10 AWG |
| CSA | 28 to 10 AWG |