Transformer technical parameters table
Product Description
Main technical parameter
Preassembled substation technical parameter table
| Serial number |
Name |
Unit |
Technical specification |
| 1 |
rated voltage |
KV |
10/0.4(high voltage/low voltage) |
| 2 |
maximum working voltage |
KV |
12(high-pressure side) |
| 3 |
rated frequency |
HZ |
50 |
| 4 |
rated capacity |
KVA |
50-1600 |
| 5 |
1-minute power frequency withstand voltage |
KV |
35 |
| 6 |
lightning impulse voltage |
KV |
75 |
| 7 |
type of cooling |
|
Oil immersed in self-cooling |
| 8 |
High voltage backup fuse breaking current |
KA |
50 |
| 9 |
Breaking the current of the plug-in fuse |
KA |
2.5 |
| 10 |
environment temperature |
ºC |
-35~+40 |
| 11 |
Coil allowable temperature rise |
ºC |
65 |
| 12 |
No load voltage regulation |
|
±5%or±2x2.5% |
| 13 |
noise grade |
db |
50 |
| 14 |
level of protection |
|
IP43 |
Transformer technical parameters table
Selection of new S9 series transformer body, low loss, good overload capacity, strong short-circuit resistance, all fasteners are anti-loose treatment, no lifting core; S10 series and S11 series transformers with better performance are also available.
| Capacity kva |
Voltage |
no-load current |
open circuit losses |
impedance voltage |
load loss |
| high voltage |
low voltage |
S9 |
S10 |
S11 |
S9 |
S10 |
S11 |
4.0 |
S9 |
S10 |
S11 |
| 50 |
10±5% ±2x2.5% |
0.4 |
2.0 |
1.9 |
0.75 |
0.17 |
0.15 |
0.12 |
0.87 |
0.83 |
0.87 |
| 63 |
1.9 |
1.8 |
0.7 |
0.2 |
0.18 |
0.14 |
1.04 |
0.99 |
1.04 |
| 80 |
1.9 |
1.7 |
0.7 |
0.25 |
0.22 |
0.175 |
1.25 |
1.2 |
1.25 |
| 100 |
1.8 |
1.55 |
0.65 |
0.29 |
0.26 |
0.2 |
1.5 |
1.42 |
1.5 |
| 125 |
1.7 |
1.45 |
0.65 |
0.34 |
0.3 |
0.235 |
1.8 |
1.72 |
1.8 |
| 160 |
1.6 |
1.3 |
0.6 |
0.4 |
0.36 |
0.27 |
2.2 |
2.12 |
2.2 |
| 200 |
1.5 |
1.2 |
0.55 |
0.48 |
0.43 |
0.33 |
2.6 |
2.5 |
2.6 |
| 250 |
1.4 |
1.1 |
0.5 |
0.56 |
0.5 |
0.39 |
3.05 |
2.9 |
3.05 |
| 315 |
1.4 |
1.0 |
0.45 |
0.67 |
0.29 |
0.465 |
3.65 |
3.45 |
3.65 |
| 400 |
1.3 |
1.0 |
0.4 |
0.8 |
0.71 |
0.56 |
4.3 |
4.15 |
4.3 |
| 500 |
1.2 |
1.0 |
0.4 |
0.96 |
0.85 |
0.67 |
5.15 |
4.82 |
5.15 |
| 630 |
1.1 |
0.8 |
0.4 |
1.2 |
1.6 |
0.81 |
4.5 |
6.2 |
5.86 |
6.2 |
| 800 |
1.0 |
0.7 |
0.35 |
1.4 |
1.23 |
0.98 |
7.5 |
7.2 |
7.5 |
| 1000 |
1.0 |
0.6 |
0.3 |
1.7 |
1.5 |
1.15 |
10.3 |
9.8 |
10.3 |
| 1250 |
0.9 |
0.6 |
0.27 |
1.95 |
1.72 |
1.36 |
12.0 |
12.2 |
12.0 |
main technical parametersLoad switch technical parameter table
The load switch is an oil-immersed, three-phase linkage switch with, spring operating mechanism. It can be operated with load division and brake, and its division and speed have nothing to do with the size of the operating force. There are two stations, four stations T-type, four stations V-type, and so on.
| Serial number |
Name |
Unit |
Four-station loop load switch |
Two-station load switch |
| 1 |
rated voltage |
A |
630 |
315 |
| 2 |
Rated short-circuit closing current |
KA |
31.5 |
31.5 |
| 3 |
rated short-time current |
KA |
12.5 |
12.5 |
| 4 |
Rated short endurance time |
S |
2 |
2 |
| 5 |
mechanical life |
Next |
2000 |
2000 |
| 6 |
Lightning impulse withstand voltage peak full wave |
Phase to phase |
KV |
75 |
75 |
| 7 |
isolating fracture |
|
85 |
85 |
| 8 |
1min power frequency withstand voltage |
Phase to phase |
KV |
42 |
42 |
| 9 |
isolating fracture |
|
48 |
48 |
| 10 |
Rated peak withstand current |
KA |
31.5 |
31.5 |
Fuse technical parameters(The company oil oil-immersed fuse selection configuration recommendation table)
| Serial number |
Three-phase transformer capacity(KVA) |
XRNT rated current(A) |
PRNT1 Overload protection rated current(A) |
| 1 |
30 |
10 |
6 |
| 2 |
50 |
16 |
8 |
| 3 |
80 |
16 |
10 |
| 4 |
100 |
20 |
15 |
| 5 |
125 |
25 |
15 |
| 6 |
160 |
31.5 |
25 |
| 7 |
200 |
40 |
25 |
| 8 |
250 |
50 |
40 |
| 9 |
315 |
63 |
40 |
| 10 |
400 |
63 |
40 |
| 11 |
500 |
80 |
50 |
| 12 |
630 |
100 |
50/65 |
| 13 |
800 |
125 |
65 |
| 14 |
1250 |
160 |
100 |
| 15 |
1600 |
200 |
140 |