AAC is primarily used in urban areas with short spacing and close supports. All aluminium conductors are manufactured from one or more strands of aluminium wire, depending on the intended application. AAC is also extensively utilized in coastal regions due to its high corrosion resistance.
Minfeng AAC conductors are manufactured in compliance with the following standards:
ACSR conductors are widely employed in power transmission lines across various voltage levels due to their advantageous characteristics, including simple structure, convenient installation and maintenance, low cost, and large transmission capacity. They are particularly suitable for installation across rivers, valleys, and areas with unique geographical features.
AAAC conductors are engineered to provide superior strength-to-weight ratios and enhanced electrical properties. They offer excellent sag-tension characteristics and superior corrosion resistance compared to ACSR conductors. The lighter weight, comparable strength and current carrying capacity, reduced electrical losses, and improved corrosion resistance have made AAAC widely accepted in distribution and medium to high voltage transmission lines.
All Aluminum-Alloy Conductors (AAAC) can be supplied to meet various international standards:



| Code Word | Size (AWG or kcmil) | Stranding | Individual Wire Diameter (inches) | Complete Cable Diameter (inches) | Weight Per 1000ft. (lbs.) | Rated Strength (lbs.) |
|---|---|---|---|---|---|---|
| Peachbell | 6 | 7 | 0.0612 | 0.184 | 25 | 563 |
| Rose | 4 | 7 | 0.0772 | 0.232 | 39.2 | 881 |
| Iris | 2 | 7 | 0.0974 | 0.292 | 62.3 | 1350 |
| Pansy | 1 | 7 | 0.1093 | 0.328 | 78.5 | 1640 |
| Pop | 1/0 | 7 | 0.1228 | 0.368 | 99.1 | 1990 |
| Geranium | 1/0 | 19 | 0.0745 | 0.371 | 99 | -- |
| Aster | 2/0 | 7 | 0.1309 | 0.416 | 124.9 | 2510 |
| Buttercup | 2/0 | 19 | 0.0837 | 0.416 | 125 | -- |
| Phlox | 3/0 | 7 | 0.1548 | 0.464 | 157.5 | 3040 |
| Primrose | 3/0 | 19 | 0.094 | 0.467 | 158 | -- |
| Oxlip | 4/0 | 7 | 0.1739 | 0.522 | 198.7 | 3830 |
| Sunflower | 4/0 | 19 | 0.1055 | 0.525 | 198 | -- |
| Code Word | Size (AWG or KCMIL) | Stranding (Al/Stl) | Diameter (inches) | Weight Per 1000ft (lbs.) |
|---|---|---|---|---|
| 6Turkey | 6/6 | 6/1 | 0.198 | 36.1 |
| Swan | 4 | 6/1 | 0.25 | 57.4 |
| Swanate | 4 | 7/1 | 0.257 | 67 |
| Sparrow | 2 | 6/1 | 0.316 | 91.3 |
| Sparate | 2 | 7/1 | 0.325 | 106.7 |
| Robin | 1 | 6/1 | 0.355 | 115.2 |
| Raven | 1/0 | 6/1 | 0.398 | 145.3 |
| Quail | 2/0 | 6/1 | 0.447 | 183.1 |
| Pigeon | 3/0 | 6/1 | 0.502 | 230.8 |
| Penguin | 4/0 | 6/1 | 0.563 | 291.1 |
| Code Word | Size (KCMIL) | Stranding | Diameter (ins.) | Weight Per 1000 Feet (lbs.) | Rated Strength (lbs.) |
|---|---|---|---|---|---|
| Akron | 30.58 | 7 | 0.198 | 28.5 | 1110 |
| Alton | 48.69 | 7 | 0.25 | 45.4 | 1760 |
| Ames | 77.47 | 7 | 0.316 | 72.2 | 2800 |
| Azusa | 123.3 | 7 | 0.398 | 115 | 4460 |
| Anaheim | 155.4 | 7 | 0.447 | 144.9 | 5390 |
| Amherst | 195.7 | 7 | 0.502 | 182.5 | 6790 |
| Alliance | 246.9 | 7 | 0.563 | 230.2 | 8560 |