Specifications
Certification :
UL;ISO9001;ISO13485;IATF16949;TPU
Use :
Charging
Return&refunds :
You can apply for a refund up to 30 days after receipt of the products.
Jacket :
TPE
Voltage :
380v
Exterior material :
customize:PVC、PE、LSFOH、silicone rubber
Lead Time :
7-15days
Plug Type :
IEC 62196-2 (Type 2), SAE J1772 Type 1
insulating materials :
customize:PVC、PE 、XLPE、EPR、SIR
Core :
Multiple
Type :
Slow EV Charging Station
Shipping Cost :
about shipping cost and estimated delivery time.
Conductor Type :
Twisted wire
Place of Origin :
Guangdong, China
Brand Name :
Linke
MOQ :
1000m
Price :
Negotiable
Packaging Details :
According to requirement
Delivery Time :
7-15 days
Payment Terms :
Advance 30% deposit and ship after receiving 70% final payment
conductor material :
copper/Tinned Copper
rated voltage :
300-600V
Conductor :
Bare Copper
Structure :
3034/0.20
rated temperature :
-60± 200℃
Package Size :
50.00cm * 50.00cm * 50.00cm
Customization :
Available
Model NO. :
LK-EV102
specifications :
0.1-450mm²
Samples :
US$ 1000/PCS 1 PCS(Min.Order) |
package :
By roll
colour :
customize
Description
Type 2 to Type 2 EV Charging Cable
High-performance AC EV Charger cable available in 7kW, 11kW, and 22kW configurations with length options of 5m, 7m, and 10m.
Product Images
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers

Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers

Brand LINKE Cross Section (mm²) 0.01-500mm²
Wire Gauge (AWG) [e.g., 24AWG, 28AWG] Conductor Tinned Copper /bare copper, based on client's requirements
Insulation material PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other Jacket Material [PVC/PU/Rubber/Braid/etc.]
Certifications RoHS/REACH/UL/CE/IP68/etc Custom Length [e.g., 1m, 3ft, 5m ±5% tolerance]
Cable Type [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] Shielding [Shielded/Unshielded/Braid Shield]
Impedance [e.g., 75Ω (for coaxial cables)] Printing/Logo [Text/Label/Logo, max. 20 characters]
Bend Radius [e.g., ≥5× cable diameter] Current Rating [e.g., 5A]
Voltage Rating [e.g., 30V AC/DC] Connector Material [Gold-plated/Nickel-plated/Brass/etc.]
Connectors [e.g., USB Type-C, 3.5mm Jack, RJ45] Jacket XLPE or PE or PVC RUBBER
Delivery Time 7-14 days after confirming the order Colors [Black/White/Red/Custom Pantone/etc.]
temperature Minus-70℃to 350℃(-70℃ ~ 350℃) Package Roll/box/plate/Custom
Supporting Services custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated)
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Technical Specifications
SPECIFICATION CABLE NAME EV Cable
CABLE SPEC 2C×80mm2+1C×25mm2+2C×4mm2+(3C×0.75mm2)(P2)+(7C×0.75mm2
RoHS Compliant
Detailed Construction
Item A: 2C×80mm2 B: 1C×25mm2 C: 1C×4mm2 D: (3C×0.75mm2)(P2) E: (7C×0.75mm2)
CONDUCTOR
Material Bared copper stranded
Size 2580/0.20 ±0.008mm 798/0.20 ±0.008mm 224/0.15±0.008mm
+10/1#Tinsel+1000D Kevlar
40/0.15±0.008mm+
10/0.19mmTinsel+200DKevlar
40/0.15±0.008mm+
10/0.19mmTinsel+200D Kevlar
O.D.(Ref.) 12.40±0.25mm 7.00±0.20mm 2.70±0.15mm 1.40±0.10mm 1.40±0.10mm
Electrical Characteristics
Rated voltage: DC 1000V
Rated temperature: Jacket -40~90ºC, Insulation -40~125ºC
Max. conductor resistance(20ºC):
A:0.242Ω/km B:0.78Ω/km C:4.95Ω/km D&E:26Ω/km
Insulation Voltage withstand: AC 2.5kV/5min
Completed cable Voltage withstand: AC 3.5kV/15min
Min. Insulation resistance: 500MΩ.km
Physical Properties
Tensile strength: ≥20MPa
Elongation: ≥300%
Flame test: GB/T 18380.12-2008
Min. Bend radius: 6*OD
Abrasion resistance: ≥2000times
Low-temperature impact test: -40ºC×16H, No crack
Cable Structure Specifications
NO. Conductor mm2 Insulation 20ºC Conductor Resistance (Ω/KM)
EV-YJ 1.5 48/0.20 ≤12.7
EV-YJ 2.5 80/0.20 ≤7.60
EV-YJ 4 128/0.20 ≤4.71
EV-YJ 6 196/0.20 ≤3.14
EV-YJ 10 322/0.20 ≤1.82
EV-YJ 16 513/0.20 ≤1.16
EV-YJ 25 798/0.20 ≤0.743
EV-YJ 35 1121/0.20 ≤0.527
EV-YJ 50 1596/0.20 ≤0.368
EV-YJ 70 2242/0.20 ≤0.259
EV-YJ 95 3034/0.20 ≤0.196
Key Features
  • Conductor: Flexible Bare annealed copper wire
  • Insulation: Silicone material
  • Available in Black, Orange, Red, Yellow, or Blue jacket colors
  • Single & double insulated options
  • SQ MM sizes (European style): 4 sq mm to 240 sq mm
  • AWG sizes (North American style): 0AWG-10AWG
  • Wide temperature range: -60°C to 200°C
  • Low viscosity appearance for easy handling
Certifications & Standards
  • UL1007, UL1185, UL1672, UL10070, UL10483
  • UL1015, UL1569, UL10012, UL10269
  • UL2095, UL2129, UL2468, UL2586, UL2725
  • UL20233, UL20280, UL20963, UL2103, UL2463
  • UL2517, UL2587, UL2835, UL20276, UL20549
  • UL21198, 2104, UL2464, UL2576, UL2661
  • UL2919, UL20279, UL20886, UL21664
  • ISO9001 and ISO13485, TS16949
  • CNR - Appliance Wiring Material
Frequently Asked Questions
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last. Welcome to visit us. We'll pick you up in Shenzhen.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. You'd better order a suitable quantity to avoid the high freight. Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity. We can make a discount and afford the freight. Please kindly contact us.
5. Does your company accept OEM production?
Yes, we can print your company name and even customize the quality card to promote your company.
Send your message to this supplier
Send Now

Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers

Ask Latest Price
Watch Video
Certification :
UL;ISO9001;ISO13485;IATF16949;TPU
Use :
Charging
Return&refunds :
You can apply for a refund up to 30 days after receipt of the products.
Jacket :
TPE
Voltage :
380v
Exterior material :
customize:PVC、PE、LSFOH、silicone rubber
Contact Supplier
video
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers
Type 2 EV Charging Cable with Bare Copper Conductor and TPE Jacket for 7kw 11kw 22kw AC EV Chargers

Linke Cable Technology (DongGuan) CO.,LTD

Verified Supplier
3 Years
guangdong, dongguan
Since 2004
Business Type :
Manufacturer
Total Annual :
800000-1000000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement