Specifications
Brand Name :
LABNOVATION
Model Number :
LD-100
Certification :
IFCC, NGSP, CE
Place of Origin :
Shenzhen, China
MOQ :
1
Price :
Negotiation
Payment Terms :
D/A, D/P, T/T
Supply Ability :
100/Day
Delivery Time :
15-20 working days
Packaging Details :
Carton
Name :
Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test
Principle :
Borate Affinity
Sample types :
Whole blood
Test Time :
≤2 minutes
Sample Volume :
4μL
Dimension :
192(L)*128(W)*108(H)mm
Description

Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test

The Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test is a fully automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c).


Feature

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).


Specification

Model LD-100
Method Boronate Affinity
Operating Type Fully automatic
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Shelf life of test kit 9 months
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm


Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.


Certificate

Boronate Affnity POCT HbA1c Analyser 2 Minutes For Glycated Hemoglobin TestBoronate Affnity POCT HbA1c Analyser 2 Minutes For Glycated Hemoglobin Test

Send your message to this supplier
Send Now

Boronate Affnity POCT HbA1c Analyser 2 Minutes For Glycated Hemoglobin Test

Ask Latest Price
Brand Name :
LABNOVATION
Model Number :
LD-100
Certification :
IFCC, NGSP, CE
Place of Origin :
Shenzhen, China
MOQ :
1
Price :
Negotiation
Contact Supplier
Boronate Affnity POCT HbA1c Analyser 2 Minutes For Glycated Hemoglobin Test

Labnovation Technologies, Inc.

Active Member
4 Years
shenzhen
Since 2001
Business Type :
Manufacturer
Total Annual :
10000000-50000000
Employee Number :
100~600
Certification Level :
Active Member
Contact Supplier
Submit Requirement