High Power 132KV Bare Conductor ACSR Dog Conductor Eco Friendly for Transmission
The 132KV ACSR Dog Conductor is a high-strength, eco-friendly overhead transmission line conductor designed for efficient power distribution. Its application includes:
Transmission Networks: Primarily used in high-voltage (132KV) overhead transmission lines to transmit electricity over long distances with minimal energy loss.
Eco-Friendly Design: Composed of aluminum conductors reinforced with steel, it is fully recyclable and aligns with sustainable infrastructure goals.
Durability & Performance: Suitable for diverse terrains (rivers, valleys) due to its robust structure, low maintenance, and high transmission capacity.
Standards Compliance: Manufactured to meet international standards like IEC 61089, ensuring global compatibility.
Steel Core: Central galvanized steel strands offer superior mechanical strength to withstand high tension and wind loads.
Aluminum Conductors: Outer layers of aluminum ensure optimal electrical conductivity for efficient power transmission.
Stranded Design: The stranded construction enhances flexibility, allowing for easy installation and adaptability to various terrains.
Voltage Rating: Rated for 132KV, making it suitable for high-voltage transmission networks.
High Strength-to-Weight Ratio: The steel core provides exceptional tensile strength without excessive weight.
Corrosion Resistance: Galvanized steel core and aluminum conductors offer durability in harsh environmental conditions.
Eco-Friendly: Fully recyclable materials align with sustainable infrastructure goals.
| BS215 PART2 | ||||||||||||
| Code | Cross | No.of wires | Wire daimeter | Diameter | Mass per | Rated | Maximum | |||||
| name | section | unit length | strength | DC resistance | ||||||||
| Al | Steel | Total | Al | Steel | Core | Cond. | at 20°C | |||||
| mm2 | mm2 | mm2 | Al | Steel | mm | mm | mm | mm | kg/km | kN | ohm/km | |
| MOLE | 10.6 | 1.77 | 12.4 | 6 | 1 | 1.5 | 1.5 | 1.5 | 4.5 | 42.8 | 4.14 | 2.7027 |
| SQUIRREL | 21 | 3.5 | 24.5 | 6 | 1 | 2.11 | 2.11 | 2.11 | 6.33 | 84.7 | 7.87 | 1.3659 |
| GOPHEL | 26.2 | 4.37 | 30.6 | 6 | 1 | 2.36 | 2.36 | 2.36 | 7.08 | 106 | 9.58 | 1.0919 |
| WEASEL | 31.6 | 5.27 | 36.9 | 6 | 1 | 2.59 | 2.59 | 2.59 | 7.77 | 127.6 | 11.38 | 0.9065 |
| FOX | 36.7 | 6.11 | 42.8 | 6 | 1 | 2.79 | 2.79 | 2.79 | 8.37 | 148.1 | 13.21 | 0.7812 |
| FERRET | 42.4 | 7.07 | 49.5 | 6 | 1 | 3 | 3 | 3 | 9 | 171.2 | 15.27 | 0.6757 |
| RABBIT | 52.9 | 8.81 | 61.7 | 6 | 1 | 3.35 | 3.35 | 3.35 | 10.1 | 213.5 | 18.42 | 0.5419 |
| MINIK | 63.1 | 10.5 | 73.6 | 6 | 1 | 3.66 | 3.66 | 3.66 | 11 | 254.9 | 21.67 | 0.454 |
| SKUNK | 63.2 | 36.9 | 100.1 | 12 | 7 | 2.59 | 2.59 | 7.77 | 13 | 463 | 52.79 | 0.4568 |
| BEAVER | 75 | 12.5 | 87.5 | 6 | 1 | 3.99 | 3.99 | 3.99 | 12 | 302.9 | 25.76 | 0.382 |
| HORSE | 73.4 | 42.8 | 116.2 | 12 | 7 | 2.79 | 2.79 | 8.37 | 14 | 537.3 | 61.26 | 0.3936 |
| RACOON | 78.8 | 13.1 | 92 | 6 | 1 | 4.09 | 4.09 | 4.09 | 12.3 | 318.3 | 27.06 | 0.3635 |
| OTTER | 83.9 | 14 | 97.9 | 6 | 1 | 4.22 | 4.22 | 4.22 | 12.7 | 338.8 | 28.81 | 0.3415 |
| CAT | 95.4 | 15.9 | 111.3 | 6 | 1 | 4.5 | 4.5 | 4.5 | 13.5 | 385.3 | 32.76 | 0.3003 |
| HARE | 105 | 17.5 | 122.5 | 6 | 1 | 4.72 | 4.72 | 4.72 | 14.2 | 423.8 | 36.04 | 0.273 |
| DOG | 105 | 13.6 | 118.5 | 6 | 7 | 4.72 | 1.57 | 4.71 | 14.2 | 394 | 32.65 | 0.2733 |
| COYOTE | 131.7 | 20.1 | 151.8 | 26 | 7 | 2.54 | 1.91 | 5.73 | 15.9 | 520.7 | 45.86 | 0.2192 |
| COUGAR | 131.5 | 7.31 | 138.8 | 18 | 1 | 3.05 | 3.05 | 3.05 | 15.3 | 418.8 | 29.74 | 0.2188 |
| TIGER | 131.2 | 30.6 | 161.9 | 30 | 7 | 2.36 | 2.36 | 7.08 | 16.5 | 602.2 | 57.87 | 0.2202 |
| WOLF | 158.1 | 36.9 | 194.9 | 30 | 7 | 2.59 | 2.59 | 7.77 | 18.1 | 725.3 | 68.91 | 0.1829 |
| DINGO | 158.7 | 8.81 | 167.5 | 18 | 1 | 3.35 | 3.35 | 3.35 | 16.8 | 505.2 | 35.87 | 0.1814 |
| LYNX | 183.4 | 42.8 | 226.2 | 30 | 7 | 2.79 | 2.79 | 8.37 | 19.5 | 841.6 | 79.97 | 0.1576 |
| CARACAL | 184.2 | 10.2 | 194.5 | 18 | 1 | 3.61 | 3.61 | 3.61 | 18.1 | 586.7 | 40.74 | 0.1562 |
| PANTHER | 212.1 | 49.5 | 261.5 | 30 | 7 | 3 | 3 | 9 | 21 | 973.1 | 92.46 | 0.1363 |
| JAGUAR | 210.6 | 11.7 | 222.3 | 18 | 1 | 3.86 | 3.86 | 3.86 | 19.3 | 670.8 | 46.57 | 0.1366 |
| LION | 238.3 | 55.6 | 293.9 | 30 | 7 | 3.18 | 3.18 | 9.54 | 22.3 | 1093.4 | 100.47 | 0.1213 |
| BEAR | 264.4 | 61.7 | 326.1 | 30 | 7 | 3.35 | 3.35 | 10.1 | 23.5 | 1213.4 | 111.5 | 0.1093 |
| GOAT | 324.3 | 75.7 | 400 | 30 | 7 | 3.71 | 3.71 | 11.1 | 26 | 1488.2 | 135.13 | 0.0891 |
| SHEEP | 375.1 | 87.5 | 462.6 | 30 | 7 | 3.99 | 3.99 | 12 | 27.9 | 1721.3 | 156.3 | 0.0771 |
| ANTELOPE | 374.1 | 48.5 | 422.6 | 54 | 7 | 2.97 | 2.97 | 8.91 | 26.7 | 1413.8 | 118.88 | 0.0773 |
| BISON | 381.7 | 49.5 | 431.2 | 54 | 7 | 3 | 3 | 9 | 27 | 1442.5 | 121.3 | 0.0758 |
| DEER | 429.6 | 100.2 | 529.8 | 30 | 7 | 4.27 | 4.27 | 12.8 | 29.9 | 1971.4 | 179 | 0.0673 |
| ZEBRA | 428.9 | 55.6 | 484.5 | 54 | 7 | 3.18 | 3.18 | 9.54 | 28.6 | 1620.8 | 131.92 | 0.0674 |
| ELK | 477.1 | 111.3 | 588.5 | 30 | 7 | 4.5 | 4.5 | 13.5 | 31.5 | 2189.5 | 198.8 | 0.0606 |
| CAMEL | 476 | 61.7 | 537.7 | 54 | 7 | 3.35 | 3.35 | 10.1 | 30.2 | 1798.8 | 146.4 | 0.0608 |
| MOOSE | 528.5 | 68.5 | 597 | 54 | 7 | 3.53 | 3.53 | 10.6 | 31.8 | |||
Contact us for more details



What is the 132KV ACSR Dog Conductor?
A high-voltage overhead transmission conductor with a steel core and aluminum strands, designed for efficient long-distance power distribution at 132KV.
Why is it called "Dog Conductor"?
The name derives from its historical use in dog-legged transmission lines (or "dog-leg" configurations) to navigate challenging terrain.
Where is it typically used?
Overhead transmission lines in urban, rural, and remote areas, including river crossings and mountainous regions.
How does it perform under extreme weather?
Resists corrosion, thermal expansion, and mechanical stress, maintaining efficiency in temperatures ranging from -40°C to +80°C.
What is the lifespan of a 132KV ACSR Dog Conductor?
Over 40 years with proper installation and maintenance, thanks to its robust steel core and aluminum protection.
How does it compare to other conductors (e.g., AAC or AAAC)?
Offers superior strength and sag performance compared to all-aluminum conductors (AAC), making it ideal for high-tension applications.