Specifications
Brand Name :
Zhongdong
Model Number :
AAAC
Certification :
CCC,IEC,VDE,TUV,ISO
Place of Origin :
Hebei,China
MOQ :
Negotiable
Price :
Negotiable
Payment Terms :
,L/C,T/T
Supply Ability :
500KM/Week
Delivery Time :
7-30 days based on different Qty
Packaging Details :
Wooden Drum
Range Of Application :
Overhead Transmission, Overhead Ground
Material :
Aluminum
Drum Packing :
Steel Wooden Drum
Product Name :
AAC/AAAC/ACSR/ACSS/ACCC
Per Drum Weight :
As per request
Voltage :
up to 110KV
Description

GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution



APPLICATION

Steel Wire Galvanized is suitable for overhead line stay wires, binding and jointing wires.

CONSTRUCTION

Core Material

Zinc Coating


GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089



CHARACTERISTIC

  • ‌Corrosion Resistance‌
  • High Tensile Strength
  • Surface Properties‌
  • ‌Flexibility‌
  • ‌Electrical Conductivity

SPECIFICATION

Stranding & Wire Diameler

Overall
Diameter


Sectional Area


Approximate
Weight


Breaking
Load


DC
Resistance

Alumimium

Steel


Aluminium


Steel


Total

mm

mm

mm

mm²

mm²

kg/km

kN

ohm/km

A

6/1.98

1/1.98

5.43

18.4

3.07

21.5

74.4

9.02

1.7934

6/2.47

1/2.47

7.41

28.8

4.80

33.6

116.2

13.96

1.1478

6/3.13

1/3.13

9.38

46.0

7.67

53.7

185.9

22.02

0.7174

6/3.92

1/3.92

11.80

72.5

12.10

84.6

292.8

34.68

0.4555

18/2.85

1/2.85

14.30

115.0

6.39

121.0

266.4

41.24

0.2880

18/3.19

1/6.19

16.00

144.0

7.99

152.0

458.0

51.23

0.2304

26/2.65

7/2.06

16.80

144.0

2340

167.0

579.9

69.86

0.2310

18/3.61

1/3.61

18.00

184.0

10.20

294.0

586.2

65.58

0.1800

26/3.00

7/2.34

19.00

184.0

30.00

214.0

742.3

88.52

1.1805

18/4.04

1/4.04

20.20

230.0

12.80

243.0

732.8

81.97

0.1440

26/3.36

7/2.61

21.30

230.0

37.50

268.0

927.9

110.64

0.1444

22/4.08

7/2.27

23.10

288.0

28.30

316.0

1,013.5

117.09

0.1154

26/3.75

712.92

23.80

288.0

46.90

335.0

1,159.8

138.31

0.1155

45/3.20

7/2.14

25.60

363.0

25.10

388.0

1,196.5

136.28

0.0917

26/4.21

7/3.28

26.70

363.0

59.00

422.0

1,461.4

171.90

0.09117

45/3.61

7/2.41

28.90

460.0

31.80

492.0

1,519.4

172.10

0.0722

54/3.29

7/3.29

29.70

460.6

59.70

520.0

1,738.0

201.46

0.0723

45/3.83

7/2.55

30.60

518.0

35.80

554.0

1,709.3

193.61

0.0642

54/3.49

7/3.49

31.50

518.0

67.10

585.0

1,955.6

226.64

0.0643

45/4.04

7/2.69

32.30

575.0

39.80

615.0

1,899.3

215.12

0.0578

Contact us for more details


ABOUT US


GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089



PROJECTS


GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089


WHY US



GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089

FAQ

What are the standard sizes available for GSW bare conductors?‌
GSW offers bare conductors in a range of standard sizes to accommodate various electrical applications, including common diameters and cross-sectional areas for power transmission and distribution needs.
What materials are used in manufacturing GSW bare conductors?‌
These conductors are typically made from high-quality aluminum or copper, chosen for their excellent conductivity and durability in outdoor environments.
What are the advantages of using GSW bare conductors over insulated ones?‌
Bare conductors provide superior heat dissipation, reduced cost, and ease of installation, making them ideal for overhead transmission lines where insulation is not required.
How should GSW bare conductors be installed to ensure safety?‌
Proper installation involves using appropriate hardware like insulators and spacers, maintaining clearances from structures, and following local electrical codes to prevent short circuits.
What environmental conditions are GSW bare conductors suitable for?‌
They are designed to withstand harsh weather, including rain, wind, and temperature fluctuations, though extreme conditions may require additional protective measures.
Can GSW bare conductors be used in industrial settings?‌
Yes, they are widely used in industrial applications for power distribution due to their reliability and ability to handle high current loads.
What maintenance practices are recommended for GSW bare conductors?‌
Regular inspections for corrosion, mechanical damage, and vegetation encroachment are essential to ensure long-term performance and safety.
How do GSW bare conductors compare in cost to other types of conductors?‌
They are generally more cost-effective than insulated alternatives, offering savings in material and installation expenses while maintaining efficiency.
What certifications or standards apply to GSW bare conductors?‌
These products comply with international electrical standards, ensuring quality and safety for global use in power networks.
Where can I find technical support or documentation for GSW bare conductors?‌
For detailed specifications, installation guides, or assistance, contact GSW’s customer support or visit their official website for downloadable resources.

Send your message to this supplier
Send Now

GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089

Ask Latest Price
Brand Name :
Zhongdong
Model Number :
AAAC
Certification :
CCC,IEC,VDE,TUV,ISO
Place of Origin :
Hebei,China
MOQ :
Negotiable
Price :
Negotiable
Contact Supplier
GSW Bare Conductor Aluminum Alloy Conductor Steel Reinforced for Overhead Distribution IEC61089

Zhongdong Cable Co., Ltd.

Verified Supplier
2 Years
hebei, jinzhou
Since 2004
Business Type :
Manufacturer
Total Annual :
150000000-200000000
Employee Number :
400~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement