Electric Furnace 1000°C MBF100-10 Medium-Temperature Clean Box Furnace
Product Specifications
| Attribute | Value |
| Model NO. | MBF100-10 |
| Range of Applications | Industrial |
| Type | Electric Holding Furnace |
| Usage | Ceramic Sintering |
| Fuel | Electric |
| Atmosphere | Air/O2 |
| Effective Chamber Dimensions | 450*450*500mm (W*H*D) |
| Transport Package | Wooden Packaging |
| Specification | 990*1680*1095mm |
| Trademark | Chitherm |
| Origin | China |
| HS Code | 8514101000 |
| Supply Ability | 50 Sets/Year |
| Customization | Available |
| Certification | ISO |
| Place Style | Vertical |
Product Overview
The MBF100-10 medium-temperature clean box furnace uses FEC ceramic fiber heating plates, which are resistant to acid and alkali, have good uniformity, and are simple to operate. It is suitable for various laboratories and small batch production processes.
Performance Parameters
- Product Model: MBF100-10 Medium-Temperature Clean Box Furnace
- Operating Temperature: 900°C
- Maximum Test Temperature: 1000°C
- Furnace Chamber Effective Dimensions: 450 × 450 × 500 (W × H × D)
- Inner Lining Material: Fused Quartz
- Heating Elements: FEC Ceramic Fiber Heating Plates
- Temperature Stability: ±1°C
- Furnace Chamber Temperature Uniformity: ±5°C
- Number of Temperature Control Segments: 9 segments
- Number of Temperature Control Points: 1 point
- Alarm Protection: Interlock between heating and furnace door operation, audible and visual alarms for over-temperature, open circuit, and low pressure
- Surface Temperature Rise: <35°C
- Maximum Heating Power: 22 kW
- Power Requirements: Three-phase, 380VAC, 50Hz, 30 kVA, zero-crossing control
- Equipment Weight: 500 Kg
- Installation Dimensions: 1800mm × 1850mm × 3000mm (D × W × H)
Delivery List
| Item | Note | QTY |
| Basic Compositions | Furnace | 1 unit |
| Certificates of Inspection | Furnace and major purchased components | 1 Set |
| Technical Documents | Furnace specifications, technical documents of major purchased components, etc | 1 Set |
| Key Parts | Touch screen | 1 PC |
| Temperature Controller | | 1 Set |
| FEC Heater | | 1 Set |
| Quartz Liner | | 1 Set |
| Spares | SSR | 1 PC |
Facility Requirements
- Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong airflow disturbance.
- Gas Source Conditions: Clean, dry, oil-free compressed air or oxygen, working pressure 0.2 to 0.4 MPa, gas consumption approximately 3 to 6 m³/h
- Ventilation System: Non-contact connection to the user's extraction system, with an extraction capacity greater than 10 m³/h.
- Ground requirements: Level, no obvious vibration, bearing capacity > 500Kg/m².
- Power conditions: Capacity greater than 22kVA, 3 phases 5 lines, voltage 220/380V, frequency 50Hz (according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green
- Installation site: 2000mm×2000mm×3000mm (W×H×D), installation area greater than 4m².