Electrical Specifications
| Parameter |
Specification |
| Main Power Supply |
Three-phase 200–500 V AC (±10%), 50/60 Hz |
| Control Power Supply |
24 V DC (±20%) |
| Input Continuous Current |
30 A |
| Switching Frequency |
Up to 8 kHz |
| DC Bus |
Supports common DC bus, energy feedback |
| Brake Chopper |
Built-in, maximum braking power 22 kW |
| Overload Capacity |
2.5 times rated current (short time) |
| Input Fuse |
32 A |
| Short Circuit Current Rating (SCCR) |
42,000 A rms |
| Power Consumption |
300 W (continuous current condition) |
| Output Voltage |
0–530 V AC |
| Output Frequency |
0–1600 Hz |
Model Code Analysis
HCS02.1E-W0070-A-03-NNNN
- HCS02: IndraDrive C Series (Overseas Version)
- 1E: Hardware Version
- W0070: Peak Current 70 A (continuous 28.0 A)
- A: Control Unit Type (Basic)
- 03: Design Version
- NNNN: No Additional Communication/Safety/I/O Expansion (Basic Configuration)
Core Functions and Interfaces
Communication Interface
No built-in fieldbus; requires expansion slots to add Multi-Ethernet (PROFINET/EtherNet/IP/Modbus TCP), CANopen, Profibus DP, and other protocols.
Encoder Interface
Supports Hiperface, EnDat 2.1/2.2, BiSS, SSI, Resolver, TTL, and other encoder types.
Safety Functions
No built-in safety functions (STO/SS1); requires expansion via safety modules for safety applications.
I/O and Operation
- Standard digital I/O and analog interfaces
- Built-in operation panel (4 keys + digital tube)
- Supports IndraWorks software debugging and parameter configuration
Environmental Specifications
| Parameter |
Specification |
| Operating Temperature |
0°C to +40°C (nominal); +55°C (derating) |
| Storage Temperature |
-25°C to +70°C |
| Altitude |
≤ 1000 m (derating required for higher altitudes) |
| Installation Spacing |
≥80 mm ventilation space required vertically |
| Pollution Level |
Level 2 (suitable for moderately polluted industrial environments) |