I. Basic Information
1. Brand/Series: Pepperl+Fuchs, Basic Type
2. Type: 3-wire DC PNP Normally Open (NO) Inductive Proximity Sensor
3. Mounting Method: Flush, M18*1 Thread
4. Connection Method: 2m PVC cable (3 cores, 0.34 mm²); V1 suffix model with M12 connector also available
5. Dimensions: Diameter 18 mm, Length 56 mm
6. Weight: 112 g
7. Protection Rating: IP67, IP68, IP65/IP66
II. Electrical Parameters
| Parameters |
Specifications |
| Operating Voltage |
6~36 V DC (standard 10~30 V DC) |
| Output Current |
0~200 mA |
| Voltage Drop |
≤1 V |
| No-load Current |
≤10 mA |
| Leakage Current |
max 20 μA |
| Switching Frequency |
Up to 1950 Hz |
| Protection Functions |
Reverse polarity protection, pulse short circuit protection |
| Status Indicator |
Yellow LED |
III. Detection and Environmental Parameters
1. Rated Detection Distance: 5 mm; Reliable Detection Distance: 0~4.05 mm
2. Material Attenuation Coefficient: rAl=0.35, rCu=0.29, r304 Stainless Steel = 0.73, r Brass = 0.44 (based on mild steel)
3. Ambient Temperature: -40℃~+85℃ (same for storage)
4. Housing Material: Brass plated with white bronze; Sensing Surface PBT (green)
5. Certifications: Compliant with IEC/EN 60947-5-2, UL/cULus, DNV GL Classification Society Certification
IV. Application Scenarios and Selection Tips
1. Applicable Scenarios: Metal workpiece positioning/limiting in machine tools, conveyor lines, packaging equipment, and automotive production lines; resistant to oil, dust, and humid environments.
2. Selection Criteria
- Suffix -V1: M12 plug connection (no cable)
- Suffix -5M: 5m long cable
- E0/E1/E2: E2 corresponds to PNP output; E0/E1 is usually NPN
3. Wiring: 3-wire system (brown +, blue -, black signal output); reverse polarity is strictly prohibited; shielding and grounding are recommended for long cables.