Power input
| Rated input voltage (V) |
Three-phase 380V (-15%) to 480V (+10%) |
| Rated input current (A) |
4.8A (SHD), 3.4A (HD) |
| Rated frequency (Hz) |
50Hz or 60Hz, within the allowable range of 47 to 63Hz |
Power output
| Rated motor capacity (kW) |
Super Heavy Duty (SHD): 0.75kW Heavy Duty (HD): 1.5kW |
| Rated output (kVA) |
2.6kVA |
| Rated Current (A) |
4.8A (SHD), 3.4A (HD) |
| Rated output voltage (V) |
0 - Input Voltage, with an error less than 5% |
| Output frequency (Hz) |
0~400Hz |
Technical control performance
| Control method |
V/F control mode, without PG sensorless vector control (SLVC) mode, closed-loop vector control (with PG) mode, torque control mode |
| Motor type |
Asynchronous motor, permanent magnet synchronous motor |
| Speed control range |
1:50 (V/F), 1:200 (SLVC), 1:1500 (with PG) |
| Speed control accuracy |
±0.2% (without PG vector control), ±0.01% (with PG vector control) |
| Speed fluctuation |
±0.1% (without PG vector control) |
| Torque response |
<10ms (without PG vector control) |
| Torque control accuracy |
±5% |
| Starting torque |
0.3Hz 200% (without PG vector control) |
| Overload capacity |
200% rated current for 3 seconds, 150% rated current for 1 minute, allowed once every 5 minutes (Super Heavy Duty mode) 150% rated current for 1 minute, allowed once every 5 minutes (Heavy Duty mode) |
Operating control characteristics
| Frequency setting method |
Keyboard number setting, analog quantity setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS RTU/Profibus/PROFINET communication setting, etc. Realize the combination of settings and the switching of setting channels. |
| Automatic voltage regulation function |
When the grid voltage changes, it can automatically maintain the output voltage constant. |
| Fault protection function |
Provide comprehensive fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss, overload, ground fault, motor stall, short circuit, etc. |
| Speed tracking restart function |
Realize the smooth and impact-free startup of a rotating motor |
| Simulated input |
3 channels, AI1/AI2: 0(2) to 10V / 0(4) to 20mA, AI3: -10 to 10V |
| Simulation output |
2 channels, AO1/AO2: 0 to 10V / 0(4) to 20mA |
| Digital input |
8-channel opto-isolated general input, PNP/NPN selectable, maximum frequency 1kHz |
| Digital output |
3-channel open collector output, maximum frequency 1kHz |
| Relay output |
3-channel programmable relay outputs, contact capacity: 3A/AC250V, 1A/DC30V |
Others
| DC reactor |
Not equipped as standard, external optional |
| Installation method |
Wall-mounted installation, push-through installation |
| Brake unit |
Built-in brake unit as standard |
| EMC filter |
No built-in EMC filter as standard; external C2/C3 filters available as options Optional filters: IEC61800-3 C2, IEC61800-3 C3 |
| Operating environment temperature |
-10 to 40 degrees Celsius. For use above 40 degrees Celsius, the performance will be reduced by 1% per degree up to 50°C. |
| Altitude |
Below 1000 meters, no derating required. Above 1000 meters, the rated current decreases by 1% for every 100 meters increase in altitude. |
| Protection level |
IP20 |
| Note |
The frequency converter should be installed in a metal distribution box that meets IP20 standards. |
| Safety regulations |
Meet the requirements of CE, UL, cUL, RoHS certification, integrated STO (Safe Torque Off) SIL3/PLe |
| Cooling method |
Forced air cooling |
| Dimensions (W*H*D) |
100mm * 180mm * 140mm |
| Weight |
Approximately 2.4kg |