This heavy-duty low voltage frequency converter inverter is specifically engineered for HVAC and water pump applications. As a high-efficiency industrial VFD drive, it provides stable motor speed regulation, outstanding compatibility, and reliable energy-saving performance, making it ideal for long-term operation across various industrial environments.
Low-Voltage Inverter Series
FRENIC-Ace (E3) High Performance Standard Series
| Model |
Power (kW) |
Voltage |
Rated Current (A) |
Key Features |
| FRN0001E3S‑2C |
0.1 |
1Ph 200V |
0.8 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0002E3S‑2C |
0.2 |
1Ph 200V |
1.4 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0004E3S‑2C |
0.4 |
1Ph 200V |
2.5 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0007E3S‑2C |
0.75 |
1Ph 200V |
4.0 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0012E3S‑2C |
1.1 |
1Ph 200V |
6.0 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0022E3S‑2C |
2.2 |
1Ph 200V |
10.0 |
Vector control, Modbus/Profinet, Built-in EMC |
| FRN0001E3S‑4C |
0.1 |
3Ph 400V |
0.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0002E3S‑4C |
0.2 |
3Ph 400V |
0.9 |
Vector control, Multi-protocol, Global certifications |
| FRN0004E3S‑4C |
0.4 |
3Ph 400V |
1.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0007E3S‑4C |
0.75 |
3Ph 400V |
2.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0012E3S‑4C |
1.1 |
3Ph 400V |
3.8 |
Vector control, Multi-protocol, Global certifications |
| FRN0022E3S‑4C |
2.2 |
3Ph 400V |
5.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0037E3S‑4C |
3.7 |
3Ph 400V |
8.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0055E3S‑4C |
5.5 |
3Ph 400V |
12.5 |
Vector control, Multi-protocol, Global certifications |
| FRN0075E3S‑4C |
7.5 |
3Ph 400V |
17.0 |
Vector control, Multi-protocol, Global certifications |
| FRN0110E3S‑4C |
11 |
3Ph 400V |
25.0 |
Vector control, Multi-protocol, Global certifications |
| FRN0150E3S‑4C |
15 |
3Ph 400V |
33.0 |
Vector control, Multi-protocol, Global certifications |
| FRN0185E3S‑4C |
18.5 |
3Ph 400V |
40.0 |
Vector control, Multi-protocol, Global certifications |
| FRN0220E3S‑4C |
22 |
3Ph 400V |
48.0 |
Vector control, Multi-protocol, Global certifications |
FRENIC-MEGA (G2) Heavy-Duty High Power Series
| Model |
Power (kW) |
Voltage |
Rated Current (A) |
Key Features |
| FRN0004G2S‑2C |
0.4 |
3Ph 200V |
3.1 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0007G2S‑2C |
0.75 |
3Ph 200V |
5.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0015G2S‑2C |
1.5 |
3Ph 200V |
8.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0022G2S‑2C |
2.2 |
3Ph 200V |
11.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0037G2S‑2C |
3.7 |
3Ph 200V |
17.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0055G2S‑2C |
5.5 |
3Ph 200V |
25.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0075G2S‑2C |
7.5 |
3Ph 200V |
33.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0110G2S‑2C |
11 |
3Ph 200V |
45.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0150G2S‑2C |
15 |
3Ph 200V |
60.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0185G2S‑2C |
18.5 |
3Ph 200V |
73.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0220G2S‑2C |
22 |
3Ph 200V |
86.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0300G2S‑2C |
30 |
3Ph 200V |
115.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0370G2S‑2C |
37 |
3Ph 200V |
142.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0450G2S‑2C |
45 |
3Ph 200V |
170.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0550G2S‑2C |
55 |
3Ph 200V |
210.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0750G2S‑2C |
75 |
3Ph 200V |
280.0 |
Heavy duty, 200% overload/10s, Long service life |
| FRN0900G2S‑2C |
90 |
3Ph 200V |
340.0 |
Heavy duty, 200% overload/10s, Long service life |
Note: Additional models available for 3Ph 400V configuration with power ratings up to 630kW. Contact for complete specifications.
Frequently Asked Questions
Q1: What is the difference between the overseas version and the domestic Fuji inverter?
A1: The overseas version comes with CE, UL and RoHS certifications, supports global grid voltage of 400V/480V, and is better adapted to local usage habits in Europe, America and Southeast Asia.
Q2: Do I need extra parts for overseas installation?
A2: No extra parts needed for most regions. For dusty or high-temperature areas, a dust cover is recommended. An output reactor is required if the motor cable is too long.
Q3: Can it fit local power grid voltage?
A3: Yes. The 4C model supports 380V-480V wide voltage, compatible with most grids in Europe, Southeast Asia and the Middle East.
Q4: Can it drive a standard 3-phase motor directly?
A4: Absolutely. It works with ordinary asynchronous motors directly without any motor modification.
Q6: Which series is the most universal for general machines?
A6: FRENIC-Ace E3 for standard equipment, FRENIC-MEGA G2 for heavy-duty high-power, and FRENIC-Mini C2 for small machines.
Q13: Can it run 24/7 continuously?
A13: Yes. Industrial-grade design supports long-time continuous operation for factories, water plants and buildings.