The GE Critical Power FLTR75V05 Filter Module is engineered to significantly reduce conducted common-mode and differential-mode noise on the input or output lines of high-frequency switching power supplies. Designed to meet stringent international EMI requirements from agencies like the FCC and CISPR, this module is crucial for high-density power applications where internal filters may be insufficient. It is optimized for use with high-frequency switching DC-to-DC power modules and is suitable for distributed power architectures in telecom and datacom environments. The module's compact design and PC board mountability, combined with its effective noise filtering capabilities, make it an essential component for achieving robust EMI performance and meeting regulatory standards.
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Model | FLTR75V05 | |||||
| Input Voltage: Continuous | Vi | 75 | Vdc | |||
| Input Voltage: Transient (100 ms) | Vi, trans | 100 | Vdc | |||
| Voltage from GND to Either Input Lead | 1500 | Vdc | ||||
| Operating Case Temperature | Tc | 40 | 100 | C | ||
| Storage Temperature | Tstg | 55 | 125 | C | ||
| Resistance per Leg | R | 20 | m | |||
| Maximum Average Current (TA = 92 C, 2.0 m/s air) | I max | 5 | A | |||
| Maximum Average Current (TA = 75 C, natural convection) | I max | 3.3 | A | |||
| Common-mode Insertion Loss (50 circuit, 500 kHz) | 37 | dB | ||||
| Differential-mode Insertion Loss (50 circuit, 500 kHz) | 43 | dB | ||||
| Dimensions (L x W x H) | 25.4 x 25.4 x 10.2 mm (1.0 x 1.0 x 0.4 in.) | mm (in.) | ||||
| Device Code | FLTR75V05Z | CC109102654 | ||||
| Device Code (Short pins) | FLTR75V055Z | CC109128237 |