Description:
1. The furnace body adopts high insulation aluminum silicate fiber board insulation, stainless steel board packaging, beautiful and generous, to ensure the efficient operation of the furnace, thermal efficiency up to 80%;
2. The structure of the combustion chamber is designed according to the flame geometry, and considering the structure diagram of the burner and the size of the combustion chamber match, at the same time in order to prevent the damage of deflagration to the heating furnace, the furnace end is equipped with explosion-proof door;
3. The overall operation of the equipment is simple, smooth operation, the least water, low equipment failure rate.
4. The heating furnace is automatically controlled, and the output load is automatically adjusted according to the medium temperature or water bath temperature required by the process.
5. The local instrument shows the water level, water temperature, medium temperature, combustion state, etc.
6. The instrument control system automatically adjusts the output power of the heating furnace, and detects the safety interlock condition of the system to achieve the unattended function;
8. The burner control system adopts PID control, effectively prevent the lag because of the sharp fluctuations caused by the traffic control, make the medium temperature control at + 2 ℃;
9. Optimized windscreen and windproof design reduces the hidden danger of flameout;
10. The fuel tank and pressure regulating valve set are insulated with an insulated box:
11. The furnace type is indirect heating furnace, the coil is set according to the process requirements, to meet the requirements of large flow, different temperature rise;
12. The heating furnace coil manufacturing and material apply the anti - sulfur, anti - carbon dioxide corrosion;
13. The burner adopts automatic proportional adjustment burner. When the gas supply pressure is stable, the combustion effect is very good.
14. The compound proportional regulator can achieve a high ratio of 1:8.The burner shell is made of special materials which are corrosion resistant and wear free.
15. Automatic ignition;
16. Flame monitoring;
17. Flame off protection function: (electromagnetic valve and flame monitoring interlock);
Gas automatic leak control;
18. High/low gas pressure, low combustion air pressure, flameout, cheat detection fault, etc.
19. Considering the combustion efficiency and anti-freezing in winter, preheating the fuel gas.
![]()
| 1 | Capacity | 5 ~ 100x10* Nm3 / d |
| 2 | Heating power | 60 ~ 360 kw |
| 3 | Working medium | Natural gas |
| 4 | Inlet pressure | 1.6 ~ 60 mpa |
| 5 | Design pressure in front of two stage Angle valve | 16 ~ 60 mpa |
| 6 | Heating throttle pressure | 2.5-9.0 MPa |
| 7 | throttling status | Single/double pass |
| 8 | Inlet and outlet diameter | Dn50, Dn65 |
| 9 | Installation dimensions | ≤ 10X3X3.5 m |
| 10 | Weight | 10-50 tons |

Perfect quality system and testing facilities Strong R & D and design capabilities

120 R&D team provide the system solutions. Timely delivery capability

Perfect quality system and testing facilities Good after-sales service and operation technical support