Specifications
Brand Name :
ESEGAS
Model Number :
ESE-LASER-100
Product Name :
TDLAS Gas Analysis System
Sampling Gas Temperature :
≥180℃
Resolution :
1ppm
Range :
10ppm/50ppm/200ppm/1000ppm
Measured Gas :
NH3/HCL/HF
Gas Conditioning System :
Yes
Measurement Accuracy :
1%FS
Sampling type :
extractive type
Description

TDLAS Gas Analyzer With Gas Conditioning System High Temperature Extraction Type Monitoring HCL/HF/NH3

Here are some key details about TDLAS (Tunable Diode Laser Absorption Spectroscopy) gas analyzers:


- Make use of tunable diode lasers that can be precisely tuned to the absorption wavelength of the gas to be measured.
- Lasers in the near-infrared range are commonly used, matching the absorption bands of gases like methane, H2O, CO2, CO, NH3.
- The laser beam passes through the sample gas and the amount of laser light absorbed by the target gas molecules is measured.
- The gas concentration is proportional to the measured absorption following the Beer-Lambert law.
- Extremely fast measurement response times, on the order of seconds or less. Enables real-time analysis.
- High sensitivity and selectivity. Can measure gas concentrations down to ppm or ppb levels.
- Suitable for process control and monitoring applications requiring speed and precision.
- Provides in-situ measurements without requiring extractive sampling.
- Immune to cross-interferences from other gases or changes in temperature and pressure.
- Tuning the laser wavelength mitigates interferences from other gases. Multiple lasers can be used in one TDLAS analyzer.
- Requires periodic calibration using a known concentrated certified reference gas.
- Main applications include measurement of gases like CO2, CO, CH4, H2O, NH3 in industries such as natural gas, chemicals, oil refining.
- Major suppliers include Yokogawa, ABB, Siemens, Emerson, Coulton, NEO Monitors.


In summary, TDLAS analyzers provide rapid and sensitive in-situ gas quantification for critical process monitoring applications.

Applications

☑ SCR, incineration & combustion processes

☑ Emission monitoring:Power generation, engine development, waste incineration furnaces, …

☑ Environmental monitoring: Landfill & green-house gases, livestock, …

☑ Chemical engineering: Production control & monitoring …

☑ Safety: Leak detection, refrigeration, toxic gases, .

☑ Climate control & monitoring: Livestock, climate chambers & rooms

Measured gas HCL/HF/NH3
Method Tunable Diode Laser Spectrometry (TDLAS)
Range HCL/HF: 0-50ppm,0-100ppm,0-500ppm( Customized)

NH3:Above 20ppm

Accuracy ± 1% full scale reading depending on integration stability (temperature & pressure)
Precision 1ppm
Displayed resolution 0.1ppm
Response time Less than 15S (at gas flow rate of 3 L/min)
Sampling Gas Temperature ≥180℃
Analog Output 4`20mA DC, Insulating output, maximum load is 900 ohm,
Digital Output RS232/485
Power Supply 90-240VAC / 50/60Hz 120W
Warm up time 30 minutes
Interface RS232
Ambient Temperature Temp:-10-50℃ Humidity:0-90%RH
Dimension 760(H)×500(L)×255(W)mm(analysis cabinet)

700(H)×450(L)×210(W)mm(control cabinet)

Send your message to this supplier
Send Now

10ppm - 1000ppm TDLAS Gas Analyzer Instrument With Gas Conditioning System

Ask Latest Price
Brand Name :
ESEGAS
Model Number :
ESE-LASER-100
Product Name :
TDLAS Gas Analysis System
Sampling Gas Temperature :
≥180℃
Resolution :
1ppm
Range :
10ppm/50ppm/200ppm/1000ppm
Contact Supplier
10ppm - 1000ppm TDLAS Gas Analyzer Instrument With Gas Conditioning System

Enviro Solutions Technology Co.,Ltd

Active Member
3 Years
wuhan
Since 2008
Business Type :
Manufacturer, Seller
Employee Number :
100~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement