Specifications
Brand Name :
ESEGAS
Model Number :
ESE-LASER-100
Product Name :
Safety TDLAS Gas Analyzer
Sampling Gas Temperature :
≥180℃
Range :
10ppm/50ppm/200ppm/1000ppm
Measured Gas :
NH3/HCL/HF
Gas Conditioning System :
Yes
Measurement Accuracy :
1%FS
Resolution :
1ppm
Sampling type :
extractive type
Description

TDLAS NH3 Analyzer GAS Analyzer With Gas Conditioning System High Temperature Extraction Type Monitoring HCL/HF/NH3

TDLAS stands for Tunable Diode Laser Absorption Spectroscopy, while NH3 refers to ammonia. A TDLAS NH3 analyzer is an instrument that utilizes tunable diode laser technology to measure the concentration of ammonia in a gas sample.


TDLAS works by using a laser that emits light at a specific wavelength, which is absorbed by the target gas—in this case, ammonia. The amount of light absorbed by the gas is directly proportional to the concentration of the gas. By measuring the absorption of light at the specific wavelength, the TDLAS analyzer can determine the concentration of ammonia in the gas sample.


TDLAS NH3 analyzers are commonly used in various applications, including environmental monitoring, industrial processes, and agricultural settings. They provide accurate and real-time measurements of ammonia concentrations, allowing for efficient control and monitoring of ammonia levels in different environments.

Applications

☑ SCR, incineration & combustion processes

☑ Emission monitoring:Power generation, engine development, waste incineration furnaces, …

☑ Environmental monitoring: Landfill & green-house gases, livestock, …

☑ Chemical engineering: Production control & monitoring …

☑ Safety: Leak detection, refrigeration, toxic gases, .

☑ Climate control & monitoring: Livestock, climate chambers & rooms

Measured gas HCL/HF/NH3
Method Tunable Diode Laser Spectrometry (TDLAS)
Range HCL/HF: 0-50ppm,0-100ppm,0-500ppm( Customized)

NH3:Above 20ppm

Accuracy ± 1% full scale reading depending on integration stability (temperature & pressure)
Precision 1ppm
Displayed resolution 0.1ppm
Response time Less than 15S (at gas flow rate of 3 L/min)
Sampling Gas Temperature ≥180℃
Analog Output 4`20mA DC, Insulating output, maximum load is 900 ohm,
Digital Output RS232/485
Power Supply 90-240VAC / 50/60Hz 120W
Warm up time 30 minutes
Interface RS232
Ambient Temperature Temp:-10-50℃ Humidity:0-90%RH
Dimension 760(H)×500(L)×255(W)mm(analysis cabinet)

700(H)×450(L)×210(W)mm(control cabinet)

Send your message to this supplier
Send Now

Safety TDLAS Gas Analyzer NH3 / HCL / HF With Gas Conditioning System

Ask Latest Price
Brand Name :
ESEGAS
Model Number :
ESE-LASER-100
Product Name :
Safety TDLAS Gas Analyzer
Sampling Gas Temperature :
≥180℃
Range :
10ppm/50ppm/200ppm/1000ppm
Measured Gas :
NH3/HCL/HF
Contact Supplier
Safety TDLAS Gas Analyzer NH3 / HCL / HF With Gas Conditioning System

Enviro Solutions Technology Co.,Ltd

Active Member
3 Years
wuhan
Since 2008
Business Type :
Manufacturer, Seller
Employee Number :
100~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement