Specifications
Brand Name :
XINGJIN
Model Number :
WZ-Q/T-EZ6-XJ60;WZ-Q/T-EJ45-XJ60
Certification :
GSG\TUV\GB6653-2008
Place of Origin :
Guangzhou,China
MOQ :
100 set system
Price :
Pricing based on quantity
Payment Terms :
T/T, L/C
Supply Ability :
30000set/month
Delivery Time :
15-20days
Packaging Details :
Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Density :
1.05g/cm3 ±0.1g/cm3
Melting point temperature :
170℃±10℃
Nominal working pressure :
5.7Mpa
Maximum working pressure :
12.1Mpa
Operating temperature range :
(0~49)℃
Maximum length of fire detection tube :
25m
Maximum loading factor :
0.6kg/L
Description
Temperature-Sensing, Self-Actuated Fire Extinguishing System

Temperature-sensing, self-actuated fire extinguishing devices are an advanced class of fire suppression equipment developed both domestically and internationally. They are fixed, non-electric, and self-actuated, requiring no power source or traditional fire detection and alarm equipment. The entire system consists solely of a fire extinguishing agent storage cylinder and a flexible fire detection tube. The fire detection tube integrates fire detection, device activation, and fire extinguishing agent release. It can be conveniently positioned closest to any potential ignition source. In the event of a fire, the fire detection tube ruptures due to heat, instantly releasing the fire extinguishing agent for targeted extinguishing.

Types and Working Principle
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems

Direct CO2

Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems

Indirect CO2

The fire detection tube is connected to the fire extinguishing agent container through a container valve and fixed above the most likely fire source to detect the fire source. When a fire occurs, the fire detection tube softens and bursts at the highest temperature point. The pressure drop in the fire detection tube activates the container valve, and the fire extinguishing agent is released through the burst hole of the fire detection tube to extinguish the fire. At the same time, the alarm bell sounds, notifying the user that the fire extinguishing device has been activated and that the device needs to be confirmed, the system needs to be repaired, and the fire extinguishing agent needs to be refilled.

System Application Scope

The temperature-sensing automatic fire extinguishing system solves the long-standing fire prevention problem in fire-prone spaces such as electrical equipment, control boxes, and distribution boards — a problem that has long plagued the fire protection industry. Currently, this system has been widely used in power plants, telecommunications, broadcasting, petrochemical, and railway systems in China, accumulating a wealth of successful experience.

1. Suitable Firefighting Locations
  • Microwave rooms, decimeter wave rooms, meter wave rooms, substations, and uninterruptible power supply rooms within radio and television transmission towers
  • Programmable switching rooms, control rooms, and signaling transfer point rooms within communication systems
  • Control rooms, electronic equipment rooms, computer rooms, relay rooms, and substations in power plants
  • Areas where cables cross, are densely packed, and where intermediate joints are located
  • Substation cabinets, elevator control cabinets, and cable trays with trough boxes or bridges
  • Other locations with relatively enclosed enclosures for special or critical equipment
2. Applicable Fire Types

2.1 Carbon dioxide-filled fire-detection tube automatic fire-extinguishing devices can be used to extinguish the following fires:

  • Fires of flammable gases where the gas source can be shut off before extinguishing the fire
  • Fires of Class A, B, and C liquids or fusible solids such as paraffin and asphalt
  • Fires of solid surfaces and deep-seated fires of some solid materials such as cotton, fabric, and paper
  • Electrical fires

2.3 Carbon dioxide-filled fire-detection tube automatic fire-extinguishing devices must not be used to extinguish the following fires:

  • Fires of chemicals containing oxidants, such as nitrocellulose and gunpowder
  • Fires of reactive metals such as potassium, sodium, magnesium, titanium, and zirconium
  • Fires of metal hydrides such as potassium hydride and sodium hydride
Direct-Type Temperature-Sensing, Self-Actuating Fire Extinguishing Devices

Main components include a container containing fire extinguishing agent, a container valve, a pressurized fire detection tube that releases the agent and has fire detection capabilities, a pressure gauge, a one-way valve, a pressure switch, an alarm, and a dedicated connector for the fire detection tube.

The fire detection tube is a high-tech non-metallic composite product. It combines long-term leak resistance, flexibility, and effective temperature sensitivity. After pressurization, it bursts within a certain temperature range to release the extinguishing agent or transmit a fire signal.

Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Indirect-Type Temperature-Sensing, Self-Actuating Fire Extinguishing Devices

Main components include a container containing fire extinguishing agent, a container valve, a pressurized fire detection tube, a release tube, a nozzle, a pressure gauge, a one-way valve, a pressure switch, an alarm, and a dedicated connector for the fire detection tube.

Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Carbon Dioxide Direct Fire Extinguishing Device Parameters
Device Technical Parameters
Device Type Device Release Type Nominal Working Pressure Maximum Working Pressure Operating Temperature Range Minimum Agent per Unit Volume Max. Fire Detection Tube Length Max. Release Tube Length Maximum Loading Factor
Carbon dioxide temperature-sensing self-starting fire extinguishing device Direct 5.7 MPa 12.1 MPa (0~49)℃ 2.5 kg/m³ 25 m -- 0.6 kg/L
Device Type and Model
Device Type Model Specifications Agent Filling Amount (kg) Effective Protection Scope (m³) Max. Fire Detection Tube Length (m) Max. Release Tube Length (m) Device Release Type
Carbon dioxide temperature-sensing self-starting fire extinguishing device WZ-Q/T-EZ6-XJ60 6 2.4 25 -- Direct
Carbon Dioxide Indirect Fire Extinguishing Device Parameters
Device Technical Parameters
Device Type Device Release Type Nominal Working Pressure Maximum Working Pressure Operating Temperature Range Minimum Agent per Unit Volume Max. Fire Detection Tube Length Max. Release Tube Length Maximum Loading Factor
Carbon dioxide temperature-sensing self-starting fire extinguishing device Indirect 5.7 MPa 12.1 MPa (0~49)℃ 1.5 kg/m³ 25 m 12 m 0.6 kg/L
Device Type and Model
Device Type Model Specifications Agent Filling Amount (kg) Effective Protection Scope (m³) Max. Fire Detection Tube Length (m) Max. Release Tube Length (m) Device Release Type
Carbon dioxide temperature-sensing self-starting fire extinguishing device WZ-Q/T-EJ45-XJ60 45 30 25 12 Indirect
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Send your message to this supplier
Send Now

Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems

Ask Latest Price
Watch Video
Brand Name :
XINGJIN
Model Number :
WZ-Q/T-EZ6-XJ60;WZ-Q/T-EJ45-XJ60
Certification :
GSG\TUV\GB6653-2008
Place of Origin :
Guangzhou,China
MOQ :
100 set system
Price :
Pricing based on quantity
Contact Supplier
video
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems
Auto-Activating Flexible Fire Detection Tube with Direct Release for Electrical Cabinet Fire Trace Tube Systems

Guangzhou Xingjin Fire Equipment Co.,Ltd.

Verified Supplier
11 Years
guangdong, guangzhou
Since 2010
Business Type :
Manufacturer, Exporter
Total Annual :
600000-1200000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement