This cabinet type 120L red HFC-227ea gas suppression system packages a full total flooding installation into one lockable steel enclosure, making it the practical choice for server rooms, telecom shelters and small technical spaces where a pipe network would be over-engineered and over-priced. Inside the cabinet, a 120 litre red cylinder holds up to 114 kg of HFC-227ea clean agent at 2.5 MPa, together with the release valve, flexible discharge hose, solenoid actuator, pressure gauge and the detection and control board.
The unit operates as a standalone zone: smoke and heat detectors watch the protected room, the panel confirms the alarm, a 30 second delay allows occupants to leave, and the agent floods the enclosure in under ten seconds, extinguishing the fire without leaving residue on circuit boards, cable trays or documents.
| Model | GQQ120 cabinet type |
|---|---|
| Extinguishing agent | HFC-227ea (heptafluoropropane) |
| Cylinder capacity | 120 L, red epoxy coated |
| Maximum filling weight | 114 kg |
| Storage pressure | 2.5 MPa at 20 °C |
| Relief pressure | 5.0 ± 0.225 MPa |
| Discharge time | ≤ 10 s |
| Working temperature | 0 °C to 50 °C |
| Power supply | DC 24 V / 1.6 A with battery backup |
| Cabinet dimensions | 550 x 550 x 1900 mm (L x W x H) |
| Zone configuration | Single zone standard, dual zone on linked cabinets |
| Certification | CCC, CNAS, CMA, ILAC-MRA |
The unit is designed for compact, high-value rooms that sit inside a working building: server and network rooms, telecom base station shelters, UPS and battery cabinets, substation control rooms, laboratory instrument rooms, hospital equipment suites, archive and document stores, library stack areas, small clean rooms and control cabins on production lines. It is equally suited to retrofit projects, because the cabinet needs only a floor anchor, a 220V supply and a wall penetration for the discharge nozzle, and it can be installed while the surrounding facility stays in operation.
Every cabinet leaves the factory pre-piped, pre-wired and pressure tested, with the nozzle position matched to the room volume declared on the order. Site work is limited to anchoring, power connection and a discharge test of the actuator circuit. The cylinder is refillable after a genuine discharge, the solenoid and detectors are plug-in replaceable, and the control board logs alarm and fault history for maintenance review. A five-year quality guarantee applies to the cylinder and valve, supported by eight-hour technical assistance on working days.
Systems ship in a plywood outer case with bubble bag wrapping and paper edge protection, strapped and sealed against moisture for container transport. Each unit is accompanied by an agent filling certificate, a hydrostatic and leak test report, a wiring diagram and an English installation manual. Standard lead time is 15 to 20 working days after payment or L/C confirmation, and annual capacity exceeds 30,000 sets, allowing mixed container loads with other fire fighting equipment from the same factory.