A10VSO71DRS/32R-VPB22U99 A10VSO100 DFLR/31R-PPA12N00 A10VSO100DFR1/31R-VPA12N00 A10VSO100DR/32R-VPB12N00 A10VSO100DRS/32R-VPB12N00 Rexroth Germany variable piston pump
hydraulic system | high pressure | electric | cast iron | construction machinery |
hydraulic oil | variable | vertical | Rexroth | plunger pump | hydraulic | |
Edge standing | wooden box | nationwide | pipeline pump | Edge standing | plunger pump | |
Used in the mechanical industry | | | | |

HA10VS071DR/31L-PKC62N00 |
A10VO71DR/31L-PKC62N00 |
A10VO100EP1ED/53R-VRC12K07 |
A10VO100EP1DS/53R-VSC12K68 |
A10VSO140DFR1/31R-PPB12N00 |
A10V071DR/31R-PPA12N00 |
A10VSO28DFR/31R-PSA12N00 |
A10VO100EP1DS/53R-VSD12K07 |
A10VS0100DR/31R-PPA12N00 |
HA10VSO71DFR/31L-PKC62N00 |
A10VO45DFR1/31R-PSC62K04 |
A10VO100EP2D/53R-VRC12K15 |
A10VSO18DR/31L-VSC62NOO |
A10VSO140DFLR1/31R-PPB12KO1 |
A10VO28DFR1/31R-PSC61N00 |
HA10VS0100DR/31R-VSC62NOO |
A10V045DR/31R-VPA12NOO |
A10VSO71DFR1/31L-PKC62NOO |
FAQ;
Critical installation requirements include:
- Shaft alignment: Ensure precise coaxiality between the pump shaft and motor shaft. For high-speed or high-torque applications, use a dial indicator to verify alignment (radial and angular runout should meet the manufacturer’s specifications) and recheck periodically.
- Suction line design: Avoid overly long, narrow, or sharply bent suction hoses to minimize suction resistance. The suction filter should be sized appropriately (to prevent pressure drops) and mounted close to the pump’s suction port.
- Mounting stability: Secure the pump and motor to a rigid base using properly torqued bolts to reduce vibration transfer during operation.
Follow these maintenance practices to extend the pump’s service life:
- Regular parameter checks: Monitor oil level (ensure it meets the tank’s minimum/maximum marks), oil temperature (ideal range: 35–55°C; avoid exceeding 60°C), and system pressure (ensure it stays within rated limits).
- Fluid and filter replacement: Replace hydraulic oil at the intervals recommended by the manufacturer (or sooner if oil analysis shows contamination). Replace the suction and return filters whenever the oil is changed, and inspect filters monthly for clogs.
- Seal inspection: Check all hydraulic connections and shaft seals for oil leakage. Replace damaged O-rings, gaskets, or shaft seals immediately to prevent air ingress or oil loss.
- Component inspection: Periodically inspect internal parts (e.g., valve plate, pistons, swashplate) for wear or damage during major overhauls, and replace worn components with genuine spare parts.