| NO. | Test item | | Criterion |
| 1 | Power consumption current | Quiescent current | ≤20μA |
| | | Operating current (in balanced mode, no switching | 900μA |
| 2 | Imbalance detection | Detection timing duration | 2S |
| | | Imbalance Detection Time | 3.85S~7.68S |
| | | Unbalance Detection Voltage Value | 100mV |
| | | Balance Voltage Accuracy | -70~70mV |
| 3 | Balance Current | maximum equilibrium current | 1A |
| 4 | Battery Protection | Top Battery Overvoltage Protection Threshold | 5V |
| | | TOP_OVP Hysteresis | 350mV |
| | | Bottom Battery Overvoltage Protection Threshold. | 5V |
| | | BATC_OVP Hysteresis | 350mV |
| | | Battery Prerequisite Threshold. | 2.8V |
| | | TOP_PRECOND Hysteresis | 150mV |
| | | Bottom battery Prerequisite threshold | 2.8V |
| | | BOT_PRECOND Hysteresis | 150mV |
| 5 | Temperature | Operating temperature range | -20~+65ºC |
| | | Storage temperature range | -20~+65ºC |