The device offers superior documentation for endoscopic procedures, providing high-quality documentation. It is capable of accepting both analog and digital video signals, making it highly versatile for integration with existing endoscopy documentation systems. Additionally, the USB ports located on its back panel provide convenience by enabling easy connections to other documentation peripherals.
HK FY-MED, advocating the concept of environmental protection and saving, aims to improve the quality of endoscopic products and the service life of the products, thus helping customers to save costs. In addition, we are committed to developing endoscopic equipment and accessories for a long time so as to meet the needs of our customers. We believe that our long time working in the field of endoscopy will enable us to take our service in the field of endoscopy to the next level.
The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.

The Storz 20205520 is an image management and documentation system for endoscopic procedures, operating at 1920 x 1080 resolution. It sits between the camera chain and the hospital network: it accepts both analogue and digital video signals, captures stills and video, and exports them through the USB ports on the rear panel to documentation peripherals, a local archive or the patient record system. For a department that still records onto a monitor or a DVD recorder, this is the unit that turns those images into searchable digital files.
Plan the signal path before installation: confirm the output format of the camera chain (analogue or digital) and the resolution the display expects, then set the capture resolution accordingly. Keep the unit ventilated and avoid stacking it directly on the light source. Use only approved USB media — an unrecognised stick is the most common reason for a "capture failed" call. Each unit is powered on, checked for video input recognition, capture and USB export before dispatch, and inspected for connector and fan condition.
| Parameter | Value |
|---|---|
| Model Number | 20205520 |
| Product Name | Endoscopy Processor |
| Weight | Varies |
| Material | Plastic and Metal |
| Type | Medical Equipment |
| Condition | New/Used |