Specifications
Price :
$10,000/sets >=1 sets
Place of Origin :
China
MOQ :
one
Packaging Details :
standard packaging
Delivery Time :
Delivery time for minimum order quantity ≤ 30 days
Payment Terms :
T/T ‌L/C
Supply Ability :
100 units/day
Brand Name :
National Instruments
Model Number :
PXIe-6376
warranty :
3 months
customized support :
OEM
place of origin :
American
brand name :
National Instruments
model number :
PXIe-6376
Description


Name National Instruments PXIe-6376 Multifunction Module

National Instruments PXIe-6376 Multifunction Module

The PXIe-6376 (Part Number: 781475-01) Multifunction I/O Module has 8 AI (16 bits, 3.5 MS/s per channel), 2 AO, and 24 DIO. This module demonstrates a typical DAQ framework, which incorporates sensors, transducers, signal conditioning gadgets, cables to associate the different gadgets to the accessories, the X series device, the programming software and the PC. DAQ hardware digitizes signals, performs D/A conversions to produce analog output signals, and measures and controls I/O signals.

The X Series analog inputs and outputs have calibration circuitry to rectify gain and offset mistakes. The user can align the gadget to limit analog input and analog output mistakes caused by time and temperature drift at run time. No outside circuitry is essential; an inward reference guarantees high precision and solidness after some time and temperature changes.

Factory-calibration constants on the NI PXIe-6376 are permanently stored in a locally available EEPROM and cannot be changed. When the user self-aligns the gadget, as described in the Device Self-Calibration, Getting Started manual, programming stores new constants in a client modifiable area of the EEPROM. To get the Multifunction I/O Module back to its factory calibration settings, programming can duplicate the factory-calibration constants to the client modifiable section of the EEPROM.

Most PC based estimation frameworks include data acquisition (DAQ) gadgets with some type of signal modulation. Sensors and transducers for the most part require signal modulation before an estimation framework can successfully and precisely acquire the signal.

Maximum number of single-ended analog input channels: 0
Analog input resolution: 16 bits
Maximum sampling rate: 3.57 MS/s/channel
Analog output channels: 2
Maximum update rate: 3.3 MS/s/channel
Bus connector: PXI Express
Number of bidirectional digital channels: 24
Measured electrical signals: Voltage
Analog input FIFO buffer size: 8182 samples
Maximum number of differential analog input channels: 8
Current flow direction: -
Simultaneous sampling: Yes
Analog input absolute accuracy: 2688 μV
Number of counters/timers: 4

National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration

Send your message to this supplier
Send Now

National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration

Ask Latest Price
Price :
$10,000/sets >=1 sets
Place of Origin :
China
MOQ :
one
Packaging Details :
standard packaging
Delivery Time :
Delivery time for minimum order quantity ≤ 30 days
Payment Terms :
T/T ‌L/C
Contact Supplier
National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration
National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration
National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration
National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration
National Instruments PXIe-6376 Multifunction I/O Module with 24 DIO 2 AO and Factory-Calibration for OEM Integration

Shenzhen Jinxi Boyuan Technology Co., Ltd.

Verified Supplier
1 Years
guangdong, shenzhen
Since 2020
Business Type :
Distributor/Wholesaler, Agent, Exporter, Trading Company
Total Annual :
5000000-8000000
Employee Number :
100~120
Certification Level :
Verified Supplier

Find Similar Products By Category:

Contact Supplier
Submit Requirement