PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16 Hydraulic pump PV7 blade oil pump imported from Germany by Rexroth in stock
| What is the suction pressure range of the PV7 series? | -0.8 to +1 bar (absolute pressure: 0.2–1.1 bar) |
| What types of hydraulic fluids are compatible with the PV7 series? | Mineral oil (HLP) and synthetic oil (HETG/HEES); use FKM seals for synthetic fluids |
| What is the fluid viscosity range for PV7 series operation? | 10–1000 mm²/s (operation); 2–1500 mm²/s (start-up); optimal range is 16–160 mm²/s |
| What is the fluid temperature range for PV7 series operation? | -20 to +80 °C (operation); -40 to +90 °C (storage) |
| What is the noise level of the direct-acting PV7 series at 1 m distance under rated operation? | ≤63 dB(A) |
| What is the noise level of the pilot-operated PV7 series at 1 m distance under rated operation? | ≤65 dB(A) |
| What is the mounting standard for the PV7 series? | ISO 3019-2 flange; optional foot mounting for some models |
| What type of shaft connection does the PV7 series use? | ISO 4162 splined shaft; keyed shaft available on request |
| What seal materials are available for the PV7 series? | NBR (standard, for mineral oil) and FKM (optional, for synthetic oil) |
| What is the weight range of the direct-acting PV7 series? | 8–12 kg (depends on displacement) |
| What is the weight range of the pilot-operated PV7 series? | 10–35 kg (depends on displacement and control type) |
| What is the control type of the PV7-A series? | Direct-acting pressure compensation |
| What is the control type of the PV7-C/D/N/W series? | Pilot-operated pressure/flow control |
| What is the pressure rise response time of the direct-acting PV7 series? | 40–60 ms |
| What is the pressure rise response time of the pilot-operated PV7 series? | 40–60 ms |
| What is the housing material of the PV7 series? | GG25 cast iron (high strength and vibration resistance) |
| What is the material of the PV7 series rotor and stator? | 42CrMo4 alloy steel (quenched & tempered for high hardness and wear resistance) |
| What is the vane material of the PV7 series? | Wear-resistant powder metallurgy alloy (self-lubricating and anti-seizure) |
| What is the service life of the PV7 series under normal working conditions? | 8000–10000 operating hours (depends on oil cleanliness and maintenance) |
| What is the case drain flow range of the direct-acting PV7 series at rated pressure? | 1.5–2.5 l/min (varies with displacement and pressure) |

| PV7-1X/25-30RE01MC5-16WH-A234 |
| PV7-1X/100-150RE07MC5-08WH |
| PV7-1X/25-30RE01MW0-16WH |
| PV7-1X/10-20RE01MC7-10WH |
| PV7-1X/25-45RE01MC5-08 |
| PV7-1X/40-45RE37MC8-16 |
| PV7-1X/16-20RE01MW0-16WH |
| PV7-1X/16-20RE01MC3-16-P50Q25 |
| PV7-1X/100-118RE07KC0-16 |
| PV7-1X/40-71RE37MC5-08WH |
| PV7-1X/100-118RE07MC6-16 |
| PV7-1X/40-71RE37MC3-08 |
| PV7-1X/40-71RE37MC7-08WH |
| PV7-1X/10-14RE01MW0-16WH |
| PV7-1X/10-20RE01MC3-10-A497 |
| PV7-1X/16-20RE01MC3-16 |
| PV7-1X/16-20RE01MC5-16WH |
| PV7-1X/63-71RE07MC3-06-A460 |
| PV7-1X/16-30RE01MC5-08WH |
| PV7-1X/10-14RE01MC0-16-P100 |
| PV7-1X/63-94RE07MC5-08WH |
| PV7-1X/10-14RE01MC3-16 |
| PV7-1X/40-45RE37MD0-16 |
| PV7-1X/100-118RE07MC7-16WH |
| PV7-1X/25-45RE01MC5-08WH |
| PV7-1X/16-20RE01MC0-16 |
| PV7-1X/63-71RE07MC5-16WG |
| PV7-1X/63-71RE07KC3-16 |
| PV7-1X/10-20RE01MC5-10WH |
| PV7-1X/16-20RE01MC7-16 |
| PV7-1X/10-14RE01MC7-16 |
| PV7-1X/63-94RE07MC0-08 |
| PV7-1X/16-20RE01MC0-16-P100Q29 |
| PV7-1X/25-30RE01MC0-16-P100Q36 |
| PV7-1X/40-45RE37MW5-16WH |
| PV7-1X/10-14RE01MC0-16-P45 |
| PV7-1X/25-45RE01MN0-08 |
| PV7-1X/25-30RE01MC0-16 |
| PV7-1X/63-94RE07MC0-08-P75 |
| PV7-1X/63-71RE07MW5-16WH |
| PV7-1X/25-30RE01MC5-16 |
| PV7-1X/40-71RE37MD0-08 |
| PV7-1X/100-150RE07MD0-08 |
| PV7-1X/10-20RE01MC7-10 |
| PV7-1X/10-14RE01MD3-16 |
| PV7-1X/100-118RE07MW0-16WH |
| PV7-1X/100-118RE07KD0-16 |
| PV7-1X/10-14RE01MC5-16 |
| PV7-1X/63-94RE07MN0-08 |
| PV7-1X/10-14RE01KC0-16 |
| PV7-1X/40-45RE37MC3-16 |
| PV7-1X/40-45RE37MC7-16 |
| PV7-1X/16-20RE01MC0-16-C3.1 |
| PV7-1X/40-45RE37MC0-16-A446 |
| PV7-1X/100-118RE07MW0-16WG |
| PV7-1X/100-150RE07MC0-08 |
| PV7-1X/63-94RE07MC5-08WG |
| PV7-1X/16-20RE01KC0-16 |
| PV7-1X/40-55RE37MC0-08-A449 |
| PV7-1X/63-94RE07MD0-08 |
| PV7-1X/16-20RE01MD0-16-Q25 |
| PV7-1X/40-45RE37MD0-16-P50Q39 |
| PV7-1X/63-71RE07MD0-16-Q65 |
| PV7-1X/16-30RE01MC0-08 |
| PV7-1X/40-45RE37MW0-16 |
| PV7-1X/40-71RE37MC0-08 |
| PV7-1X/100-118RE07MW6-16WH |
| PV7-1X/16-30RE01MC5-08WG |
| PV7-1X/10-20RE01MC0-10 |
| PV7-1X/63-71RE07MW0-16 |
| PV7-1X/63-94RE07KC0-08 |
| PV7-1X/40-45RE37MC7-16WH |
| PV7-1X/10-14RE01MC0-16-P60Q15 |
| PV7-1X/63-71RE07KW0-16WG |
| PV7-1X/100-118RE07KC5-16 |
| PV7-1X/25-30RE01MC7-16 |
| PV7-1X/63-71RE07MC5-16 |
| PV7-1X/25-30RE01KD0-16 |
| PV7-1X/10-14RE01MC5-16WH |
| PV7-1X/10-20RE01MC0-10-P45 |
| PV7-1X/16-20RE01MW0-16 |
| PV7-1X/16-30RE01MD0-08 |
| PV7-1X/25-45RE01MD0-08 |
| PV7-1X/100-118RE07MC7-16 |
| PV7-1X/10-14RE01MC0-16-P90 |
| PV7-1X/16-20RE01MC7-16WH |
| PV7-1X/40-45RE37MD0-16-C3.1 |
| PV7-1X/40-45RE37MW0-16WG |
| PV7-1X/40-45RE37KD0-16 |
| PV7-1X/40-45RE37MC0-16-P80 |
| PV7-1X/16-30RE01MC5-08 |
| PV7-1X/100-150RE07KD0-08 |
| PV7-1X/40-45RE37MW0-16WH |
| PV7-1X/10-14RE01MD0-16 |
| PV7-1X/100-150RE07MC5-08WG |
| PV7-1X/16-30RE01MC7-08 |
| PV7-1X/63-71RE07MC0-06-A460 |
| PV7-1X/10-14RE01MC0-16 |
| PV7-1X/16-30RE01MN0-08 |
| PV7-1X/25-45RE01KC0-08 |
FAQ:
Thirty-One
Q: What is the optimal Fluid Viscosity Operating Range for Rexroth PV7 pumps?
A: Set it to 10–40 mm²/s, matching the viscosity specifications of your hydraulic fluid.
Thirty-Two
Q: How is the Fluid Contamination Particle Count Threshold defined?
A: It should be set to meet ISO cleanliness standards (≤ ISO 18/15/12) to trigger filter replacement alerts.
Thirty-Three
Q: What is the maximum allowable Fluid Moisture Content Alarm Threshold?
A: Set it to ≤0.1% to detect fluid degradation caused by water contamination early.
Thirty-Four
Q: How do I set the Fluid Replacement Maintenance Reminder Interval?
A: Set it to 100–5000 hours based on your system’s operating conditions and fluid maintenance guidelines.
Thirty-Five
Q: When does the Filter Pressure Drop Clogging Alarm Threshold trigger?
A: It triggers an alert when pressure drop exceeds 2 bar, indicating the hydraulic filter is clogged and needs replacement.
Electrical Configuration