Parameter |
Specification |
|---|---|
|
Manufacturer / Series |
Rexroth PV7-1X Series (Industrial Vane Pump) |
|
Order Code |
R900533582 |
|
Full Model |
PV7-1X/16-30RE01MC0-08 |
|
Pump Type |
Variable Displacement Vane Pump (Open Circuit) |
|
Control Type |
C (Pilot-Operated Pressure Compensator) |
|
Max. Displacement |
30 cm³/rev |
|
Max. Operating Pressure |
80 bar |
|
Frame Size |
BG 16 / NG 30 |
|
Rotation Direction |
Right-hand (R, Clockwise, viewed from shaft end) |
|
Shaft Type |
Cylindrical Shaft (Ø25 mm) with Parallel Key (ISO 3019-2) |
|
Ports |
S (Suction), P (Pressure), L (Case Drain) |
|
Port Connection |
01 (G Pipe Threads, DIN ISO 228) |
|
Mounting Flange |
4-bolt Flange (ISO 3019-2) |
|
Nominal Speed |
1450–1500 rpm |
|
Max. Flow |
~43.5–54 L/min (at 1500 rpm) |
|
Seal Material |
NBR (Nitrile) |
|
Hydraulic Fluid |
Mineral oils (HLP), HETG, HEES, HFD-U |
|
Operating Temperature |
-20°C to +80°C |
|
Weight |
Approx. 15.5 kg |
|
Country of Origin |
Germany |

| R900519094 PV7-1X/63-71RE07MD0-16 |
| R900518218 PV7-1X/63-71RE07MC5-16 |
| R900517795 PV7-1X/16-20RE01MC0-16-A184 |
| R900517464 PV7-1X/25-30RE01MC5-16 |
| R900516546 PV7-1X/100-118RE07MC5-16 |
| R900511986 PV7-1X/63-71RE07MC3-16 |
| R900511215 PV7-1X/100-118RE07MC3-16 |
| R900509506 PV7-1X/25-30RE01MD0-16 |
| R900509274 PV7-1X/16-20RE01MD0-16 |
| R900509053 PV7-1X/10-14RE01MC7-16 |
| R900506809 PV7-1X/100-118RE07MC0-16 |
| R900506808 PV7-1X/63-71RE07MC0-16 |
| R900506473 PV7-1X/16-20RE01MC5-16 |
| R900504653 PV7-1X/10-14RE01MD0-16 |
| R900502277 PV7-1X/40-45RE37MC5-16 |
| R901134661 PV7-1X/16-20RE01MD6-16 |
| R901133981 PV7-1X/63-71RE07MC3-06-A460 |
| R901129340 PV7-1X/100-118RE07MW6-16WH |
| R901100271 ABAPG-PV7/40-45C0+06-10A0/160L-4-B1/SE |
| R901083391 ABHPG-PV7/16-20C0+PF-005/132M-4-B1/LF |
| R901083371 ABAPG-PV7/63-71C5WH+GH2-008/200L-4-N0/E& |
| R901081778 PV7-1X/06-14RA01MA0-10-A452 |
| R901072539 ABPBG-PV7/100-118C0+GF3-40+GF2-08/BG160* |
| R901065655 PV7-1X/06-10RA01KA0-05 |
| R901064326 PV7-1X/40-55RE37MC0-08-A449 |
| R901062106 ABHPG-PV7/40-45C0/132S-4-B0/S * |
Q1: What is the function of the "C" control? How does it differ from the "A" control?
A: The "C" control is a pilot-operated (servo) pressure compensator. It uses a small pilot valve to control a large piston, providing faster and more sensitive response compared to the direct-operated "A" control. When system pressure reaches the set value (adjusted via handwheel), the pump quickly de-strokes to near-zero flow, maintaining pressure with minimal energy loss. It is more precise and has less hysteresis than the "A" type.
Q2: What does the "RE01MC0-08" suffix indicate?
A: This code defines the mechanical configuration and settings:
R: Right-hand rotation.
E: Cylindrical shaft with parallel key (ISO 3019-2).
01: Pipe threads (G-threads) for suction and pressure ports.
M: NBR seals, standard for mineral oils.
C: Pilot-operated pressure controller.
0: Standard version.
-08: Zero-stroke pressure adjustment range 20–80 bar.
Q3: What is the key difference between PV7-1X and the previously mentioned PV7-2X?
A: The primary differences are displacement size and pressure capability:
PV7-1X (This model): Smaller frame (BG16), 30 cm³/rev displacement, 80 bar max pressure. Lighter and more compact.
PV7-2X (Previous model): Larger frame, 25 cm³/rev displacement, 100 bar max pressure. Heavier duty.
The "1X" series is typically used in medium-power industrial applications like machine tools, while "2X" handles slightly higher pressures.
Q4: What are the critical installation requirements for this pump?
A:
Suction Conditions: Requires a flooded suction. Inlet pressure must be between 0.8 bar (abs) and 2.5 bar to prevent cavitation.
Case Drain (L Port): Must be connected directly to the tank with minimal backpressure (max 2 bar).
Shaft Warning: The shaft is not designed to handle radial or axial loads. Ensure perfect alignment with the motor using a flexible coupling.
Q5: Can this pump be used as a fixed displacement pump?
A: No. The PV7-1X/...C... is inherently a variable displacement pump. Its output flow automatically reduces to zero when system pressure reaches the set value (pressure-holding function). For fixed flow, you would need a gear pump or a fixed vane pump.