Customized 3150A Insulated Electrical Busduct Dense Enclosed Plug In Busbar Trunking
Our customized 3150A fire-resistant electrical busduct features dense enclosed plug-in insulated bus duct design for superior performance and safety in industrial applications.
We offer comprehensive busbar trunking solutions tailored to your specific requirements. Contact us via email or WhatsApp for personalized assistance and technical support. We're committed to ensuring your work experience is productive and efficient.
Selection Parameters - Dense Bus Duct Dimensions
| Current Level (A) |
XLC /4P W(mm) |
XLC /4P H(mm) |
XLC /5P W(mm) |
XLC /5P H(mm) |
| 400 | 128 | 98 | 128 | 98 |
| 500 | 128 | 108 | 128 | 108 |
| 630 | 128 | 123 | 128 | 123 |
| 800 | 128 | 138 | 128 | 138 |
| 1000 | 128 | 158 | 128 | 158 |
| 1250 | 128 | 183 | 128 | 183 |
| 1600 | 128 | 218 | 128 | 218 |
| 2000 | 128 | 268 | 128 | 268 |
| 2500 | 128 | 280 | 128 | 280 |
| 3200 | 128 | 400 | 128 | 400 |
| 4000 | 128 | 490 | 128 | 490 |
XLC Type Bus Duct Technical Specifications
Execution Standards
IEC60439.1-2000, IEC60439.2-2000, GB/T 7251.6-2015
Ambient Temperature
-5°C to +40°C (24-hour average temperature not exceeding 35°C)
Altitude
Not exceeding 2000M
Protection Grade
IP54, IP66
Unit Length
1.6, 2.5, 3.2, 6 meters (customizable from 0.5-6 meters)
Rated Operational Voltage
690V (with tap unit) / 1000V (without tap unit)
Rated Insulation Voltage (Ui)
800V (with tap unit) / 1000V (without tap unit)
Electrical Performance Parameters
| Rated Current (A) |
Resistance (uΩ/m) |
Reactance (uΩ/m) |
Total Reactance (uΩ/m) |
Voltage Drop (mV/m) |
| 400 | 88.9 | 66.5 | 289.7 | 77.5 |
| 630 | 71.1 | 62.2 | 289.7 | 81 |
| 800 | 56.4 | 39.1 | 184.2 | 77.3 |
| 1000 | 40.3 | 37.9 | 176.3 | 77.5 |
| 1250 | 33.2 | 46.6 | 221.6 | 76.4 |
| 1600 | 24.5 | 30.1 | 150.7 | 74.9 |
| 2000 | 19.5 | 7.4 | 130.7 | 73.3 |
| 2500 | 14.5 | 25.9 | 129.6 | 71.4 |
| 3150 | 11.3 | 25.3 | 120.9 | 69.7 |
| 4000 | 8.9 | 14.3 | 76.2 | 63 |
| 5000 | 6.7 | 13 | 69 | 61.4 |
Rated Short-time Withstand Current
30, 30, 50, 50, 80 KA
Rated Peak Withstand Current
63, 63, 105, 105, 176 KA
Insulation Resistance
≥20 MΩ
Electrical Clearance
≥ 10.0mm (with tapping unit) / ≥ 14.0mm (without tapping unit)
Creepage
≥ 12.5mm (with tap cell) / ≥ 16.0mm (without tap cell)
Protection Circuit Effectiveness
<0.02 Ω
Dielectric Properties
50Hz, 3750V/min, no breakdown, flashover
Installation Method
Vertical or horizontal
Number of Plug-in Interfaces
Minimum 0.5/m pieces (double-sided plug available)
Maximum Fixed Spacing
4, 4, 3, 3 meters
Balanced Load
20, 20, 25, 30 kg/m
Concentrated Load
90, 90, 90, 90 kg