Cross section(mm²) | Conductor Construction (no/mm) | Conductor Stranded OD.max(mm) | Cable OD.(mm) | Approximate weight of cable | Max Conductor Resistance(Ω/km,20°C) |
1×1.5 | 48/0.20 | 1.58 | 4.6 | 33 | 13.7 |
1×2.5 | 77/0.20 | 2.02 | 5.0 | 45 | 8.21 |
1×4 | 56/0.285 | 2.46 | 5.4 | 61 | 5.09 |
1×6 | 84/0.285 | 3.01 | 6.0 | 83 | 3.39 |
1×10 | 77/0.40 | 4.1 | 7.3 | 130 | 1.95 |
1×16 | 7×17/0.40 | 5.5 | 8.9 | 196 | 1.24 |
1×25 | 7×27/0.40 | 6.7 | 10.3 | 290 | 0.795 |
1×35 | 7×38/0.40 | 8.2 | 11.8 | 390 | 0.565 |
Q:Are they UV-resistant for outdoor use?
A: Yes, featuring dual-wall UV-resistant jackets (compatible with TUV 2 PfG 1169/08.2007) to prevent degradation from prolonged sun exposure.
Q:What conductor material is used?
A:Tinned stranded copper (Class 5 per IEC 60228) for corrosion resistance and high conductivity
Q:Are these cables flame-retardant?
A:Halogen-free, flame-retardant (per IEC 60332-1), and low-smoke for safety in fire-prone areas
Q:What certifications ensure reliability?
A:Compliant with TUV 2 PfG 1169/08.2007, IEC 62930, and EN 50618
Q:Can they be used in humid environments?
A:Yes, with moisture-resistant XLPE insulation and 85% humidity tolerance (per EN 60068-2-78)
Q: What is the expected lifespan?
A: 25+ years under standard conditions, with accelerated aging tests confirming durability
Q: Are they suitable for direct burial?
A: Armored variants support direct burial, though standard cables require conduit in high-stress zones