The OWP-BL43-426C Brushless DC (BLDC) Coolant Pump is a high-performance cooling solution tailored specifically for enterprise-grade All-Flash Arrays (AFA)—the core storage infrastructure powering data-intensive operations like databases, cloud services, and AI workloads. AFAs generate significant heat during high-speed data processing (with IOPS reaching hundreds of thousands per second), and stable thermal management is critical to avoid performance throttling or hardware failure. This pump addresses AFA cooling needs by efficiently circulating compatible coolants (such as 50-60% glycol-water mixtures, dielectric oil, or electronic fluorinated solutions), ensuring consistent temperature control across AFA components, and extending the storage system’s lifespan.
| Parameter | Details |
|---|---|
| Power Input | 24VDC (18-32VDC) |
| Rated Power | 240W |
| Flow Rate | 2400L/H (rated, @17M head); 5000L/H (max) |
| Max Lift Head | 20M |
| Compatible Coolants | Glycol (50-60%)+water, dielectric oil, mineral oil, electronic fluorinated solution |
| Connection Type | Flange Quick-Connect |
| Noise Level | ≤60dB |
| Weight | 2200g |
| Medium/Ambient Temp Range | -40℃ to +85℃ (-40°F to +185°F) |
| Storage Temp | -40℃ to +70℃ (-40°F to +158°F) |
| Connector Model | AMP282106-1 (matched plug: AMP282088-1) |
Performance

Speed Regulation & Error Feedback

Drawing