The OWP-BL43-426C Electric Coolant Pump is a high-performance, durable solution engineered to support efficient thermal management, with a primary focus on Flow Battery Energy Storage Systems. Its robust design, precise control capabilities, and wide operational compatibility make it a reliable choice for meeting the demanding cooling requirements of industrial and energy storage scenarios.
| Parameter | Details |
|---|---|
| Power Input | 24VDC (18-32VDC range) |
| Rated Power | 240W |
| Flow Rate | 2400L/H (rated, @ 17M head); 5000L/H (max) |
| Max Lift Head | 20M |
| Compatible Media | 50-60% glycol-water mixture, dielectric oil, mineral oil, electronic fluorinated solution |
| Connection Type | Flange Quick-Connect |
| Speed Control | PWM (Pulse-Width Modulation) |
| Fault Feedback | Supported |
| IP Rating | IP68 (dust-tight, water-submersible) |
| Noise Level | ≤60dB |
| Service Life | >20,000 hours |
| Weight | 2200g |
| Operating Ambient Temp | -40℃ to +85℃ (-40°F to +185°F) |
| Humidity Resistance | ≤90% |
| Connector Model | AMP282106-1 (matched plug: AMP282088-1) |
| Nozzle Size | 50.5mm (flange) |
A core application of the OWP-BL43-426C lies in thermal management for Flow Battery Energy Storage Systems—a critical function given the inherent heat generation from electrochemical polarization and ohmic polarization losses during the battery’s charge-discharge cycles. In MW-scale flow battery installations (such as grid-side energy storage stations or industrial-grade backup systems), the pump circulates compatible coolants (including 50-60% glycol-water mixtures or dielectric oil) through the battery’s closed cooling loop, specifically targeting high-heat components like the battery stack and electrolyte storage tanks.
Its rated flow rate of 2400L/H and maximum lift head of 20M ensure consistent, uniform coolant distribution across large battery stacks (comprising dozens to hundreds of individual cells), effectively preventing temperature imbalances that can lead to uneven reaction rates and accelerated capacity degradation. The pump’s wide operating ambient temperature range (-40℃ to +85℃) enables reliable performance in harsh outdoor environments—such as desert regions with extreme daytime heat or high-altitude sites—and sealed indoor facilities like data center配套储能 systems. With an IP68 protection rating, it resists dust accumulation and moisture intrusion, common hazards in outdoor energy storage yards. By maintaining the battery stack temperature within the optimal 25-45℃ range, the pump directly enhances the battery’s cycle life and ensures stable, continuous power output.
PWM & Fault Feedback

Performance Curve

Dimensions Drawing