The OWP-BL3000H-A3-1 Electronic Coolant Pump is engineered to deliver reliable, high-performance thermal management for demanding AI computing environments. Combining advanced brushless permanent magnet technology with a compact, durable design, this pump ensures stable operation even under extreme workloads, making it an ideal choice for modern data center infrastructure.
| Parameter | Details |
|---|---|
| Rated Voltage | AC380V (Operating Range: AC380V±15%) |
| Speed Range | 3000rpm - 5800rpm |
| Rated Power | 3000W |
| Head Capacity | ≥25m at Flow Rate Q=400L/min |
| Operating Ambient Temperature | -40℃ to 85℃ |
| Relative Humidity | <90%RH (during operation) |
| Protection Class | IP67 |
| Air Tightness | Test Pressure: 0.35MPa; Leakage: <0.8mL/min |
| Noise Level | ≤70dB (at rated load) |
| Service Life | >20,000 hours |
| Insulation Class | Class F |
| Medium Temperature | -40℃ to 85℃ |
The OWP-BL3000H-A3-1 Electronic Coolant Pump is specifically designed to address the intense thermal management needs of AI computing centers, where high-density servers, GPUs, and processors generate significant heat during machine learning, deep learning, and big data processing. Its key performance metrics align perfectly with the demands of these environments:
With a rated power of 3000W and flow rate of 400L/min (accompanied by ≥25m head), the OWP-BL3000H-A3-1 efficiently circulates coolant through server racks, GPU clusters, and storage systems, preventing overheating that can degrade performance or cause hardware failures. The pump’s wide operating temperature range (-40℃ to 85℃) and resistance to humidity (<90%RH) make it suitable for both indoor data halls and edge computing facilities with varying environmental conditions.
AI computing centers require 24/7 operation, and the OWP-BL3000H-A3-1 meets this need with a service life exceeding 20,000 hours and IP67 protection, ensuring resistance to dust, moisture, and mechanical stress. Its low noise level (≤70dB) contributes to a quieter working environment, while the compact, energy-efficient design helps data centers reduce their carbon footprint and operational costs—critical factors for sustainable AI infrastructure.
The pump’s airtight construction (leakage <0.8mL/min at 0.35MPa) prevents coolant loss, maintaining system integrity and reducing maintenance requirements. Whether cooling high-performance AI chips, server motherboards, or power supply units, the OWP-BL3000H-A3-1 Electronic Coolant Pump delivers consistent, reliable thermal management that supports uninterrupted AI workloads, from real-time data processing to complex model training.
Performance Curve

Dimensional Drawing