The Danfoss 060G5550 is a high-pressure MBS 3050 transmitter developed for demanding mobile and industrial hydraulic applications. Its complete specification key is MBS 3050-CA3C-E3BD10-3.
This model measures sealed-gauge pressure from 0 to 350 bar and provides a 0.5–4.5 V voltage output. It combines an M12 * 1 electrical connector, 9/16–18 UNF process connection, integrated pulse snubber and IP67 enclosure protection.
The integrated pulse snubber helps protect the sensing element against pressure peaks, cavitation and liquid hammer, making this transmitter suitable for severe hydraulic operating environments.
| Brand | Danfoss |
|---|---|
| Product Type | Pressure Transmitter |
| Series | MBS 3050 |
| Commercial Reference | 060G5550 |
| Specification Key | MBS 3050-CA3C-E3BD10-3 |
| Pressure Range | 0–350 bar / 0–5075 psi |
| Pressure Reference | Sealed Gauge |
| Output Signal | 0.5–4.5 V |
| Supply Voltage | 9–32 VDC |
| Pressure Connection | 9/16–18 UNF Male |
| Pressure Connection Standard | ISO 11926 |
| Electrical Connection | M12 * 1, 4-Pin |
| Electrical Connection Standard | IEC 61076-2-101 |
| Pulse Snubber | Integrated |
| Enclosure Rating | IP67 |
| Typical Accuracy | ±0.5% FS |
| Maximum Accuracy | ±1% FS |
| Maximum Overload Pressure | 1500 bar |
| Autofrettage Pressure | 1600 bar |
| Medium Temperature Range | -20°C to +85°C |
| Ambient Temperature Range | -25°C to +85°C |
| Response Time | Maximum 4 ms |
| M12 Pin 1 | Positive Supply |
|---|---|
| M12 Pin 2 | Positive Output |
| M12 Pin 3 | Common / Ground |
The wiring must be checked against the transmitter label and the controller documentation before power is applied.
The 060G5550 is a voltage-output transmitter and must not be connected as a replacement for a two-wire 4–20 mA transmitter without checking the controller input and wiring. Verify that the control system accepts a 0.5–4.5 V signal.
The 9/16–18 UNF process connection is not interchangeable with G 1/4 or 1/4–18 NPT connections. Confirm the process-port thread, sealing method and pressure rating before installation.
Do not insert wires, drills or cleaning tools into the pressure passage. Doing so can damage the integrated pulse snubber or alter the transmitter response.
Please provide both the Danfoss commercial reference 060G5550 and complete specification key MBS 3050-CA3C-E3BD10-3 when requesting a quotation.
Before ordering, confirm the 0–350 bar pressure range, 0.5–4.5 V output, M12 connector, 9/16–18 UNF process connection and required supply voltage. A photograph of the existing transmitter label is recommended for replacement inquiries.