PLC Splitter utilizes planar lightwave circuit technology and precision alignment processes to divide a single or dual optical input into multiple optical outputs uniformly, denoted as 1xN or 2xN configurations. These splitters are widely applied in FTTX deployments, PON networks, CATV links, and optical signal distribution systems. SUNET's PLC Splitters deliver superior optical performance, high stability, and reliability to meet diverse application requirements across various environments.
| Item | Parameter |
|---|---|
| Operating Wavelength (nm) | 1260 ~ 1650 |
| Type (1×N) | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 |
| Insertion Loss (dB) | 3.9 | 7.2 | 10.3 | 13.5 | 16.8 | 20.3 |
| Max. Uniformity (dB) | 0.8 | 0.8 | 0.8 | 1.0 | 1.5 | 2.0 |
| Min. Return Loss (dB) | 55 |
| Max. PDL (dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
| Type (2×N) | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 |
| Max. Insertion Loss (dB) | 4.2 | 7.5 | 10.6 | 13.9 | 17.2 | 20.8 |
| Max. Uniformity (dB) | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 |
| Min. Return Loss (dB) | 55 |
| Max. PDL (dB) | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.5 |
| Fiber Type | ITU-T G657A1, G657A2 and G.652D |
| Max. Temperature Stability (dB) | 0.5 (Typical 0.3) |
| Operating Temperature (°C) | -40 ~ +85 |
| Storage Temperature (°C) | -40 ~ +85 |
All measurements are made at room temperature, and connectors are not included.