This document outlines the specifications for a USB AM 90CB connector, designed for reliable performance across a wide temperature range. It details the product's electrical, mechanical, and durability characteristics, ensuring suitability for various applications.
| Item | Test Conditions | Performance | Specification |
| CONNECTION FORCE | MEASUREMENT SHALL BE MADE AFTER CONNECTING AND DISCONNECTING USING STANDARD PLUG GAUGE 3 TIMES. | INSERTION FORCE | 0.7~4Kgf |
| DISCONNECTION FORCE | 0.7~4Kgf | ||
| TERMINAL STRENGTH | A STATIC LOAD OF 0.1N/m(1kgf/cm)SHALL BE APPLIED TO THE TIP OF THE TERMINAL FOR 1 MIN IN ANY DIRECTION. THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY. ELECTRICAL, AND MECHANICAL CHARACTERISTICS SHALL BE SATISFIED. | - | - |
| CONTACT RESISTANCE | MEASURED AT SMALL CURRENT (100mA OR LESS) 1000Hz | - | 3.50m MAX |
| INSULATION RESISTANCE | APPLYA VOLTAGE OF 100V DC FOR 1 MIN TO FOLLOWING PORTIONS AFTER WHICH MEASUREMENT SHALL BE MADE: (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACT (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED. | 100M MIN | |
| DIELECTRIC STRENGTH | AC 500V ims(50~60Hz)FOR 1 MIN TRIP CURRENT:0.5mA (1) BETWEEN BODY AND CONDUCTOR (2) BETWEEN CONDUCTORS NOT TO BE CONTACL (3) BETWEEN CONDUCTORS NOT TO BE WHEN PLUG IS INSERTED. WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC. | - | |
| SOLDERABILITY TEST | THE TOP OF THE TERMINALS SHALL BE DIPPED 1mm IN THE SOLDER BATH OF 2305FOR 50.5 SECONDS. (1) SOLDER WETTING TIME SHALL BE 3 SEC OR LESS (2) THE AREA OF SOLDERING SHOULD BE OVER 75% | - | - |
| RESISTANCE TO SOLDERING HEAT TEST | SOLDERING IRON METHOD: BIT TEMPERATURE 3305 APPLICATION TIME OF SOLDERING IRON 30.5 SEC. HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL. WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OF TERMINALS. ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED. | HAND SOLDERING | A.350MAX., 2 sec Max |
| B.270MAX., 4 sec Max | |||
| HUMIDITY TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF 402 AND A HUMIDITY OF 90%TO 96% FOR 96 HR, THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 HR FOR OTHER PROCEDURES. THERE SHALL BE NO DAMAGE ON APPEARANCE. MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED. | - | - |
| HEAT TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF 702 FOR 96 HOURS, AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY MEASUREMENT. | - | - |
| COLD TEST | THE JACK SHALL BE STORED AT A TEMPERATURE OF -253 FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH. THERE SHALL BE NO DAMAGE ON APPEARANCE. MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED. | - | - |
| LIFE TEST | WITHOUT LOAD: CONNECTION AND DISCONNECTION SHALL BE MADE WITH THE MATING PLUGS AND JACKS FOR 5000 CYCLES AT A SPEED OF 10 TO 25 CYCLES/MIN. LOAD: AT RATING CONDITION (NON-INDUCTIVE LOAD) CONNECTION AND DISCONNECTION SHALL BE MADE 5000 CYCLES AT A SPEED 10 TO 20 CYCLES / MIN. | CONTACT RESISTANCE | 0.1 |
| DISCONNECTION FORCE | 0.8 TO 2.0N | ||
| OTHER | MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED. | ||
| TEMPERATURE CYCLING TEST | THE JACK SHALL BE SUBJECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE, AND THEN SHALL RETURNED ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES. THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. | INSERTION & EXTRACTION FORCE | 3 TO 20N |
| CONTACT RESISTANCE | MAX.30M | ||
| INSULATION RESISTANCE | MIN.100 M | ||
| DIELECTRIC WITHSTANDING VOLTAGE | 100VAC/MIN (BETWEEN TERMINALS) | ||
| COLD & HEAT SHOCK TEST | THE JACK SHALL BE SUBJECTED TO 5 CYCLES OF THE FOLLOWING CONDITIONS SHOWED IN THE FIGURE, AND THEN SHALL RETURNED AND ALLOWED TO REMAIN IN ROOM AMBIENT CONDITION FOR 30 MINUTES. THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART. | INSERTION & EXTRACTION FORCE | 3 TO 25N |
| CONTACT RESISTANCE | MAX.30M | ||
| INSULATION RESISTANCE | MIN.100 M | ||
| DIELECTRIC WITHSTANDING VOLTAGE | 500VAC/MIN (BETWEEN TERMINALS) |