Burn-In Test For Large-Scale Energy Storage Converters Power Conversion System
Architecture diagram


Performance parameters

System | System structure | 1 control cabinet + 6 two-way source load cabinets |
Overall size | 5800*860*2050mm |
Total floor area | 5800*1800mm(Including operation area) |
Total input voltage | Three-phase five-wire system 220Vac (rated) |
Total input current | 100A*6 |
Total input power | 50kW*6 |
Application ambient temperature | 0-40℃ |
Application environment humidity | 0-95% |
Fire protection requirements | Materials meet UL 94V0 rating |
Environmental requirements | Materials comply with Rohs, WEEE requirements |
Safety requirements | Comply with IEC62368 international standard design requirements |
Burn-in cabinet | Units/Cabinet | 2 bits/cabinet |
Burn-in product DC power | 150kW/bit |
Burn-in product DC voltage | 150-800Vdc |
Burn-in product DC current | 500A/bit |
Burn-in product AC power | 150kW/bit |
Burn-in products AC voltage | 220/380Vac/50Hz Three-phase five-wire |
Burn-in product AC current | 300A/bit |
AC Connector Type | PA350 (L1/ L2/ L3/N/PE) |
DC Connector Type | DC bronze medal |
Signal Connector Type | RJ45 (network port) |
Input power | 300kW |
Feedback power | 280kW |