| MODEL | UNIT | SPECIFICATIONS |
| Accuracy | 1/100000 | |
| Resistance of Load Bridge | OHM | >100 |
| Sensitivity Measuring Range | mV/V mV/V | 2.0 ±5.0 |
| Highest Resolution | Bits | 24bit(50Hz) |
| A/D Conversion Speed | Samples/second | Highest 4800 (18bit) |
| Speed of Output | Hz | 400,200,120,50,25,12.5,7.5 |
| Cutoff Frequency of Digital Filtering | Hz | 120,40,18,8,4,2,1,0.5,0.25 |
| Excitation Voltage of Load Bridge | v | ±10 |
| Cable from Indicator to Load cells | m | <=50 |
| Cable of communication | m | <=15 |
| Linearity | % | ±0.002 |
| Temperature effect by 10 oC | ppm/10 ℃ | 10 ppm/10 oC |
| Communication port | Isolated RS232 | |
| Communication Protocol | Modbus | |
| PC Software | V4.0 | Digital Load Cells Measuring |
| Linear correction Points | 10 setting points | |
| Baud rate selection | 9600 to 115200 | |
| Current consumption | mA | 50 |
| Operation Temperature | ℃ | -10...+40 |
| Using Temperature | ℃ | -20...+60 |
| Stocking Temperature | ℃ | -20...+60 |
| Dimension (L*W*H) | mm | 220×120×160 |