100V 20A Charge 40A Discharge Battery Aging Machine
Equipment Function
- Charging and discharging function: with constant current and voltage charging function, constant current discharging function, charging and discharging of the battery, recording the battery capacity.
- Charging and discharging interface: fully meet the requirements of battery pack charging and discharging with the same port and charging and discharging sub-port, i.e. 2 wires (P+ P-), 3 wires (P+ P- C-) and positive plate charging protection, negative pole charging protection. 3 wires (P+ P- C-) and positive plate charge protection, negative plate discharge protection of power tool batteries (CH+ P+ P-).
- Checking voltage protection:detecting whether the battery charge protection and discharge protection are working by charging and discharging the battery.
- Safety protection:anti-reverse connection protection function, power-down data protection, support continuous measurement, voltage upper and lower limit setting protection, and
- safe discharge current protection.
- Online mode: the instrument can be connected to PC through serial port for single unit or less than 5 units; for more than 5 units, a network connection mode is adopted and a network port is provided at the PC side to control up to 30 units.
- Control system: The software system adopts the classical and mature C/S mode, with two modes of communication: serial port can achieve accurate communication of several instruments in short distance, and network can achieve accurate communication of multiple instruments in long distance.
Product Specification
| Technical Parameter |
|
Input Power Supply
|
Measuring Range |
7-70V |
| |
Accuracy |
±(0.2% of reading +0.2% of range) |
|
Current
|
Charging Range |
50-5000mA |
| Charging Accuracy |
±(0.2% of reading +0.2% of range) |
| Discharge Range |
50-10000mA |
| Discharge Accuracy |
±(0.2% of reading +0.2% of range) |
| Charge |
Constant Voltage Cut-off Current |
Minimum 50mA |
| Capacity |
Accuracy |
±1% |
| Power |
Discharge Power |
≤700W |
| Time |
Inspection Time |
Real-time Collection<2S |
| |
Timing Range |
0-999h/step |
| Data Recording Interval |
≥5S |
| Middle Machine Version |
1:1 series |
| Number of Passages Per Cabinet |
12 channels, four rows and three column |
|
|
Charge
|
Charging Mode |
Constant Current and Constant Voltage Charging |
| Cut-off condition |
Voltage, Current, Relative Time, Overcharge Protection |
| Discharge |
Discharge mode |
Constant current discharge |
| |
Cut-off condition |
Voltage, Relative Time and Over-discharge Protection |
| Loop |
Cyclic measurement range |
1-999 times |
| |
Single cycle step number |
100 |
| Voltage and Current Detection Sampling |
Four-wire sampling |
| Data Base |
Using SQL database to manage test data |
| Upper computer communication mode |
Based on TCP/IP Protocol/Serial Port |
| Data Output Mode |
EXCEL/TXT/Chart |
| Communication Interface |
Mesh port |
| Chassis dimensions |
300x450x170mm |
| Cabinet size |
900x600x1900mm |
| Spatial Dimension of Discharge Battery |
900x600x130mm |