Amaxpower 2V 1500Ah Sealed VRLA AGM Deep Cycle Solar Battery (2V 1500Ah)
Factory Super long life 2V 1500Ah VRLA AGM Battery Deep cycle sealed battery for Telecommunication control equipment
AMAXPOWER CG Series is specially valve regulated sealed free maintenance 2V deep cycle AGM battery with 12-15 years design life in float service.
AMAXPOWER CG series battery adopts unique radial grid structure and super thick lead plates, in order to extend battery cycle life. Enhancing lead plates thickness ensure that battery can realize self-protect of over discharge so can avoid battery over discharge.As the most reliable and high quality battery system in the industry and perfect choice for deep cycle use, equal to LD12V series deep cycle AGM battery, reliable for backup use and solar cycle use
CG series 2V deep cycle AGM battery adopts unique grid structure, special super corrosion-resistant alloy and unique active material formula, which can improve the efficiency, so CG series battery recover performance is excellent after deep discharge even discharge to empty, also with the advantage of high durability, enough capacity and long cycle life.
1.Low Self Discharge For Lead Acid Battery
2.Heavy Duty Grids For Sealed AGM Battery
3.Maintenance-Free Operation For VRLA battery
Specification
Nominal Voltage | 2V (Single cell) | |
Nominal Capacity | 1500Ah@10 hour-rate | |
Dimension | Length | 401±2(15.80 inches) |
Width | 351±2(13.80 inches) | |
Height | 344±2(13.50 inches) | |
Total Height | 369±2(14.50 inches) | |
Weight | Approx. 100kg (220.5lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (78.8A) | 1575Ah |
10 hour rate (150A) | 1500Ah | |
5 hour rate (270A) | 1350Ah | |
3 hour rate (400A) | 1200Ah | |
1 hour rate (975A) | 975Ah | |
Max. Discharge Current (25°C/77°F) | 5250A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 0.3mΩ | |
Charge (Constant Voltage) (25°C/77°F) |
Cycle Use |
Voltage: 2.33-2.37V@25℃(77°F) Initial Charging Current: Less than 300A |
Float Use | Voltage: 2.24-2.28V@25℃(77°F) | |
Operating Temperature Range | Discharge | -20~60°C |
Charge | -10~60°C | |
Storage | -20~60°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) |
40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |
Container Material | ABS Plastic |
Industry use, Communication equipment, Telecommunication control equipment; Emergency systems; Electric power systems; Golf carts; Caravan; Power station; Nuclear power station; Solar power and wind power systems; Load leveling and storage equipment; Marine equipment; Power generation plants; Alarm systems, UPS and inverters; Medical equipment; Fire and security systems, Control equipment; Stand-by electric power.